Literature DB >> 22431456

Critical evaluation of screening techniques for emerging environmental contaminants based on accurate mass measurements with time-of-flight mass spectrometry.

Joonas Nurmi1, Jukka Pellinen, Anna-Lea Rantalainen.   

Abstract

Emerging contaminants from wastewater effluent samples were analysed, using posttarget and nontarget analysis techniques. The samples were analysed with an ultra performance liquid chromatograph-time-of-flight mass spectrometer (UPLC-TOF-MS), and the resulting data were processed with commercial deconvolution software. The method works well for posttarget analysis with prior information about the retention times of the compounds of interest. With positive polarity, 63 of 66 compounds and with negative polarity, 18 of 20 compounds were correctly identified in a spiked sample, while two compounds of a total of 88 fell out of the mass range. Furthermore, a four-stage process for identification was developed for the posttarget analysis lacking the retention time data. In the process, the number of candidate compounds was reduced by using the accurate mass of selected compounds in two steps (stages 1 and 2), structure-property relationships (stage 3) and isotope patterns of the analytes (stage 4). The process developed was validated by analysing wastewater samples spiked with 88 compounds. This procedure can be used to gain a preliminary indication of the presence of certain analytes in the samples. Nontarget analysis was tested by applying a theoretical mass spectra library for a wastewater sample spiked with six pharmaceuticals. The results showed a high number of false identifications. In addition, manual processing of the data was considered laborious and ineffective. Finally, the posttarget analysis was applied to a real wastewater sample. The analysis revealed the presence of six compounds that were afterwards confirmed with standard compounds as being correct. Three psycholeptics (nordiazepam, oxazepam and temazepam) could be tentatively identified, using the identification process developed. Posttarget analysis with UPLC-TOF-MS proved to be a promising method for analysing wastewater samples, while we concluded that the software for nontarget analysis will need improvement before it can be used in environmental analytical work with LC-TOF-MS systems.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Year:  2012        PMID: 22431456     DOI: 10.1002/jms.2964

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  9 in total

1.  A comparison of three liquid chromatography (LC) retention time prediction models.

Authors:  Andrew D McEachran; Kamel Mansouri; Seth R Newton; Brandiese E J Beverly; Jon R Sobus; Antony J Williams
Journal:  Talanta       Date:  2018-01-11       Impact factor: 6.057

2.  Nontargeted evaluation of the fate of steroids during wastewater treatment by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

Authors:  Matias Kopperi; Jevgeni Parshintsev; José Ruiz-Jiménez; Marja-Liisa Riekkola
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-21       Impact factor: 4.223

3.  Degradation of artificial sweeteners via direct and indirect photochemical reactions.

Authors:  Noora Perkola; Sanna Vaalgamaa; Joonas Jernberg; Anssi V Vähätalo
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-29       Impact factor: 4.223

4.  Comparing targeted and non-targeted high-resolution mass spectrometric approaches for assessing advanced oxidation reactor performance.

Authors:  Emily Parry; Thomas M Young
Journal:  Water Res       Date:  2016-07-25       Impact factor: 11.236

Review 5.  Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome.

Authors:  Syam S Andra; Christine Austin; Dhavalkumar Patel; Georgia Dolios; Mahmoud Awawda; Manish Arora
Journal:  Environ Int       Date:  2017-01-04       Impact factor: 9.621

6.  An Automated Methodology for Non-targeted Compositional Analysis of Small Molecules in High Complexity Environmental Matrices Using Coupled Ultra Performance Liquid Chromatography Orbitrap Mass Spectrometry.

Authors:  Kelly L Pereira; Martyn W Ward; John L Wilkinson; Jonathan Brett Sallach; Daniel J Bryant; William J Dixon; Jacqueline F Hamilton; Alastair C Lewis
Journal:  Environ Sci Technol       Date:  2021-05-18       Impact factor: 9.028

7.  Screening of additives in plastics with high resolution time-of-flight mass spectrometry and different ionization sources: direct probe injection (DIP)-APCI, LC-APCI, and LC-ion booster ESI.

Authors:  Ana Ballesteros-Gómez; Tim Jonkers; Adrian Covaci; Jacob de Boer
Journal:  Anal Bioanal Chem       Date:  2016-01-12       Impact factor: 4.142

8.  Evaluation of Sample Preparation Methods for Non-Target Screening of Organic Micropollutants in Urban Waters Using High-Resolution Mass Spectrometry.

Authors:  Nina Huynh; Emilie Caupos; Caroline Soares Peirera; Julien Le Roux; Adèle Bressy; Régis Moilleron
Journal:  Molecules       Date:  2021-11-23       Impact factor: 4.411

Review 9.  Status of hormones and painkillers in wastewater effluents across several European states-considerations for the EU watch list concerning estradiols and diclofenac.

Authors:  P Schröder; B Helmreich; B Škrbić; M Carballa; M Papa; C Pastore; Z Emre; A Oehmen; A Langenhoff; M Molinos; J Dvarioniene; C Huber; K P Tsagarakis; E Martinez-Lopez; S Meric Pagano; C Vogelsang; G Mascolo
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-29       Impact factor: 4.223

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.