Literature DB >> 22430241

Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: high transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury.

Takeshi Yoshida1, Akinori Uchiyama, Nariaki Matsuura, Takashi Mashimo, Yuji Fujino.   

Abstract

OBJECTIVE: We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to <30 cm H2O.
DESIGN: Prospective, randomized, animal study.
SETTING: University animal research laboratory.
SUBJECTS: Thirty-two New Zealand White rabbits.
INTERVENTIONS: Lavage-injured rabbits were randomly allocated to four groups to receive low or moderate tidal volume ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. MEASUREMENTS AND
RESULTS: Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at <30 cm H2O in all groups, in moderate tidal volume ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups.
CONCLUSIONS: Even when plateau pressure is limited to <30 cm H2O, combined with increased respiratory rate and tidal volume, high transpulmonary pressure generated by strong spontaneous breathing effort can worsen lung injury. When spontaneous breathing is preserved during mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.

Entities:  

Mesh:

Year:  2012        PMID: 22430241     DOI: 10.1097/CCM.0b013e3182451c40

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  71 in total

Review 1.  Evolving targets for sedation during mechanical ventilation.

Authors:  Steven D Pearson; Bhakti K Patel
Journal:  Curr Opin Crit Care       Date:  2020-02       Impact factor: 3.687

Review 2.  Spontaneous breathing during veno-venous extracorporeal membrane oxygenation.

Authors:  Stefania Crotti; Nicola Bottino; Elena Spinelli
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

3.  CrossTalk opposing view: there is not added benefit to providing permissive hypercapnia in the treatment of ARDS.

Authors:  Jeremy R Beitler; Rolf D Hubmayr; Atul Malhotra
Journal:  J Physiol       Date:  2013-06-01       Impact factor: 5.182

4.  Ten reasons to be more attentive to patients when setting the ventilator.

Authors:  Arnaud W Thille; Ferran Roche-Campo; Laurent Brochard
Journal:  Intensive Care Med       Date:  2015-04-30       Impact factor: 17.440

5.  Ventilation-induced lung injury exists in spontaneously breathing patients with acute respiratory failure: No.

Authors:  Massimo Antonelli
Journal:  Intensive Care Med       Date:  2017-01-10       Impact factor: 17.440

6.  The top ten unknowns in paediatric mechanical ventilation.

Authors:  Peter C Rimensberger; Ira M Cheifetz; Martin C J Kneyber
Journal:  Intensive Care Med       Date:  2017-05-29       Impact factor: 17.440

7.  Detection of patient-ventilator asynchrony should be improved: and then what?

Authors:  Hermann Wrigge; Felix Girrbach; Gunther Hempel
Journal:  J Thorac Dis       Date:  2016-12       Impact factor: 2.895

Review 8.  Value of measuring esophageal pressure to evaluate heart-lung interactions-applications for invasive hemodynamic monitoring.

Authors:  Xavier Repessé; Antoine Vieillard-Baron; Guillaume Geri
Journal:  Ann Transl Med       Date:  2018-09

Review 9.  The basics of respiratory mechanics: ventilator-derived parameters.

Authors:  Pedro Leme Silva; Patricia R M Rocco
Journal:  Ann Transl Med       Date:  2018-10

Review 10.  Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure.

Authors:  Bram Rochwerg; Laurent Brochard; Mark W Elliott; Dean Hess; Nicholas S Hill; Stefano Nava; Paolo Navalesi; Massimo Antonelli; Jan Brozek; Giorgio Conti; Miquel Ferrer; Kalpalatha Guntupalli; Samir Jaber; Sean Keenan; Jordi Mancebo; Sangeeta Mehta; Suhail Raoof
Journal:  Eur Respir J       Date:  2017-08-31       Impact factor: 16.671

View more