Hiroaki Yamaguchi1, Asuka Fujikawa, Hajime Ito, Nobuaki Tanaka, Ayako Furugen, Kazuaki Miyamori, Natsuko Takahashi, Jiro Ogura, Masaki Kobayashi, Takehiro Yamada, Nariyasu Mano, Ken Iseki.
Abstract
Docetaxel is a taxane family antineoplastic agent widely employed in cancer chemotherapy. We developed a liquid chromatography/tandem mass spectrometry method for the determination of docetaxel in human plasma. Plasma samples were deproteinized by acetonitrile containing internal standard paclitaxel. Chromatographic separation was performed on a TSKgel ODS-100 V 3 μm (50 mm × 2.0 mm i.d.) column using a mobile phase composed of acetonitrile-methanol-water-formic acid (50:5:45:0.1, v/v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. This method covered a linearity range of 5-5000 ng/mL with the lower limit of quantification of 5 ng/mL. The intra-day precision and inter-day precision (R.S.D.) of analysis were less than 6.7%, and the accuracy (R.E.) was within ± 9.0% at the concentrations of 5, 20, 200, and 2000 ng/mL. The total run time was 5.0 min. This method was successfully applied for clinical pharmacokinetic investigation.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22429876 DOI: 10.1016/j.jchromb.2012.02.003
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205