Literature DB >> 22429369

Detection of breast lesions using an automated breast volume scanner system.

Q Zhang1, B Hu, B Hu, W B Li.   

Abstract

OBJECTIVE: This study investigated the clinical utility of an automated breast volume scanner (ABVS) system for the detection of breast lesions.
METHODS: The breasts of 81 patients referred for ultrasonographic examination were scanned using the ABVS system and hand-held ultrasonography independently by two experienced examiners. The ABVS was used to perform scans of the breast in three directions (anteroposterior, lateral and medial), with the addition of further inferior and superior scans if necessary. The scanning data were then stored and automatically reconstructed. For hand-held ultrasonography the whole breast was scanned radially from the outside to the centre of the nipple.
RESULTS: The numbers of lesions reported by the two examiners were 89 and 99, respectively, using the ABVS (not statistically significant), compared with 60 and 85, respectively, using hand-held ultrasonography (statistically significant).
CONCLUSIONS: The ABVS system is an operator-independent method for automated breast scanning. It detected more breast lesions and provided additional information for the diagnosis of intraductal and malignant lesions compared with hand-held ultrasonography.

Entities:  

Mesh:

Year:  2012        PMID: 22429369     DOI: 10.1177/147323001204000130

Source DB:  PubMed          Journal:  J Int Med Res        ISSN: 0300-0605            Impact factor:   1.671


  6 in total

1.  Evaluation of a Novel Semi-Automated Ultrasound System for the Detection of Synovitis: A Prospective Study involving 45 Patients with Rheumatoid Arthritis.

Authors:  M Witt; J Frielinghausen; R Mueller; F Mueller; F Proft; H Schulze-Koops; M Grunke; D-A Clevert
Journal:  Ultrasound Int Open       Date:  2016-09-14

Review 2.  Automated breast ultrasound: basic principles and emerging clinical applications.

Authors:  Martina Zanotel; Iliana Bednarova; Viviana Londero; Anna Linda; Michele Lorenzon; Rossano Girometti; Chiara Zuiani
Journal:  Radiol Med       Date:  2017-08-28       Impact factor: 3.469

3.  3D Automated Breast Ultrasound System: Comparison of Interpretation Time of Senior Versus Junior Radiologist.

Authors:  Aydan Arslan; Gökhan Ertaş; Erkin Arıbal
Journal:  Eur J Breast Health       Date:  2019-07-01

4.  The clinical utility of automated breast volume scanner: a pilot study of 139 cases.

Authors:  Young Wook Kim; Seon Kwang Kim; Hyun Jo Youn; Eun Jung Choi; Sung Hoo Jung
Journal:  J Breast Cancer       Date:  2013-09-30       Impact factor: 3.588

Review 5.  Automatic breast ultrasound: state of the art and future perspectives.

Authors:  Luca Nicosia; Federica Ferrari; Anna Carla Bozzini; Antuono Latronico; Chiara Trentin; Lorenza Meneghetti; Filippo Pesapane; Maria Pizzamiglio; Nicola Balesetreri; Enrico Cassano
Journal:  Ecancermedicalscience       Date:  2020-06-23

6.  Evaluation of automated breast volume scanner for breast conservation surgery in ductal carcinoma in situ.

Authors:  Anqian Huang; Luoxi Zhu; Yanjuan Tan; Jian Liu; Jingjing Xiang; Qingqing Zhu; Lingyun Bao
Journal:  Oncol Lett       Date:  2016-07-29       Impact factor: 2.967

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.