Incidence of appropriate cardioverter-defibrillator shocks and mortality in patients with implantable cardioverter-defibrillators with ischemic cardiomyopathy versus nonischemic cardiomyopathy at 33-month follow-up.

Kaushang Gandhi1, Wilbert S Aronow, Harit Desai, Harshad Amin, Hoang M Lai, William H Frishman, Martin Cohen, Carmen Sorbera.   

Abstract

INTRODUCTION: The aim of the study was to investigate at long-term follow-up the incidence of appropriate implantable cardioverter-defibrillator (ICD) shocks and of all-cause mortality in patients with ICDs with ischemic cardiomyopathy versus nonischemic cardiomyopathy.
MATERIAL AND METHODS: ICDs were implanted in 485 patients with ischemic cardiomyopathy and in 299 patients with nonischemic cardiomyopathy, all of whom had coronary angiography. Baseline characteristics were not significantly different between the 2 groups. Follow-up was 965 days in patients with ischemic cardiomyopathy versus 1039 days in patients with nonischemic cardiomyopathy (p not significant). The ICDs were interrogated every 3 months to see if shocks occurred.
RESULTS: Appropriate ICD shocks occurred in 179 of 485 patients (37%) with ischemic cardiomyopathy and in 93 of 299 patients (31%) with nonischemic cardiomyopathy (p not significant). All-cause mortality occurred in 162 of 485 patients (33%) with ischemic cardiomyopathy and in 70 of 299 patients (23%) with nonischemic cardiomyopathy (p = 0.002).
CONCLUSIONS: The incidence of appropriate ICD shocks was not significantly different at 33-month follow-up in patients with ischemic cardiomyopathy versus nonischemic cardiomyopathy. However, patients with ischemic cardiomyopathy had a significantly higher incidence of all-cause mortality than patients with nonischemic cardiomyopathy (p = 0.002).

Entities:  

Keywords:  cardioverter-defibrillator shocks; ischemic cardiomyopathy; nonischemic cardiomyopathy

Year:  2010        PMID: 22427764      PMCID: PMC3302702          DOI: 10.5114/aoms.2010.19299

Source DB:  PubMed          Journal:  Arch Med Sci        ISSN: 1734-1922            Impact factor:   3.318


Introduction

Implantable cardioverter-defibrillators (ICDs) have been shown to reduce all-cause mortality in patients with ischemic heart disease [1-5] and in patients with nonischemic cardiomyopathy [5, 6]. At 30-month follow-up of 148 patients with ischemic heart disease and an ICD and of 60 patients with nonischemic heart disease and an ICD, ventricular tachycardia and ventricular fibrillation episodes per month were not significantly different between the 2 groups [7]. At 19-month follow-up of 105 patients with ischemic cardiomyopathy and of 48 patients with nonischemic cardiomyopathy and nonsustained ventricular tachycardia, appropriate ICD shocks occurred in 50% of patients with nonischemic cardiomyopathy versus 36% of patients with ischemic cardiomyopathy (p not significant) [8]. The incidence of appropriate ICD shocks and of all-cause mortality at long-term follow-up in a large number of patients with ischemic cardiomyopathy versus nonischemic cardiomyopathy needed to be investigated. The present article reports the incidence of appropriate ICD shocks and of all-cause mortality at 33-month follow-up in 485 patients with ischemic cardiomyopathy and in 299 patients with nonischemic cardiomyopathy.

Material and methods

There were 485 patients (83% men and 17% women), mean age 71 years, with ischemic cardiomyopathy and an ICD and 299 (78% men and 22% women), mean age 71 years, with nonischemic cardiomyopathy and an ICD. All 485 patients with ischemic cardiomyopathy had coronary angiographic evidence of obstructive coronary artery disease and a reduced left ventricular ejection fraction. All 299 patients with nonischemic cardiomyopathy had coronary angiographic evidence of no coronary artery disease and a reduced left ventricular ejection fraction. All 485 patients with ischemic cardiomyopathy and 299 patients with nonischemic cardiomyopathy had an ICD implanted for secondary or primary prevention of sudden cardiac death as a class I indication according to the American College of Cardiology/American Heart Association guidelines for implantation of an ICD in patients with ischemic or nonischemic cardiomyopathy [9]. All patients with ischemic cardiomyopathy had complete revascularization of obstructive coronary artery disease [10] by percutaneous coronary intervention or by coronary artery bypass graft surgery. At follow-up every 3 months, the ICD was interrogated to see if any shocks occurred. The shocks were further evaluated by an electro-physiologist viewing the intracardiac electrocardiograms to see if they were appropriate. Appropriate ICD shocks were for the treatment of ventricular tachycardia or ventricular fibrillation. Student’s t-tests were used to compare continuous variables between the groups. Chi-square tests and Fisher’s exact tests were used to compare dichotomous variables between the groups. The institutional review boards of Westchester Medical Center and of New York Medical College approved this study.

Results

Table I shows the baseline characteristics of the patients with ischemic cardiomyopathy and an ICD and of the patients with nonischemic cardiomyopathy and an ICD. No significant differences were present between the 2 groups.
Table I

Baseline characteristics of patients with implantable cardioverter-defibrillators with ischemic cardiomyopathy vs. nonischemic cardiomyopathy

VariableIschemic cardiomyopathy (n = 485)Nonischemic cardiomyopathy (n = 299)
Age [years]71 ±1171 ±13
Men, n (%)402 (83)233 (78)
Smoker, n (%)104 (21)56 (19)
Hypertension, n (%)285 (59)178 (60)
Diabetes mellitus, n (%) 61 (13)34 (11)
Dyslipidemia, n (%)354 (73)200 (67)
Left ventricular ejection fraction [%]32 ±1033 ±11
ACE inhibitors or angiotensin receptor blockers, n (%)245 (51)149 (50)
Beta-blockers, n (%)301 (62)180 (60)
Statins, n (%)349 (72)197 (66)
Digoxin, n (%)106 (22)72 (24)
Amiodarone, n (%)114 (24)56 (19)
Sotalol, n (%)23 (5)8 (3)
Follow-up [days]965 ±9611039 ±1037

No significant differences were present between the 2 groups ACE–angiotensin-converting enzyme

Table II shows at 33-month follow-up the incidence of appropriate ICD shocks and of all-cause mortality in patients with ischemic cardiomyopathy versus nonischemic cardiomyopathy. Table II also shows levels of statistical significance. Sixty-three of 179 ischemic cardiomyopathy patients (35%) who had appropriate ICD shocks and 31 of 93 nonischemic cardiomyopathy patients (33%) who had appropriate ICD shocks died (p not significant). Inappropriate ICD shocks occurred in 38 of 485 ischemic cardiomyopathy patients (8%) and in 21 of 299 nonischemic cardiomyopathy patients (7%) (p not significant).
Table II

Incidence of appropriate cardioverter-defibrillator shocks and of mortality in patients with ischemic cardiomyopathy vs. nonischemic cardiomyopathy

VariableIschemic cardiomyopathy (n = 485)Nonischemic cardiomyopathy (n = 299)p value
Appropriate ICD shocks, n (%)179 (37)93 (31)NS
Mortality, n (%)162 (33)70 (23)0.002

ICD-implantable cardioverter-defibrillator, NS-not significant

Of the 162 patients with ischemic cardiomyopathy who died, 91 (56%) died of congestive heart failure, 48 (30%) died of sudden cardiac death, 11 (7%) died of fatal myocardial infarction, and 12 (7%) died of a noncardiac cause. Of the 70 patients with nonischemic cardiomyopathy who died, 42 (60%) died of congestive heart failure, 22 (31%) died of sudden cardiac death, 0 (0%) died of fatal myocardial infarction, and 6 (9%) died of a noncardiac cause. The only significant difference in cause of death between the 2 groups was fatal myocardial infarction (p = 0.03 by Fisher’s exact test).

Discussion

ICDs have been shown to reduce all-cause mortality in patients with ischemic heart disease [1-5] and in patients with nonischemic cardiomyopathy [5, 6]. At 30-month follow-up of 148 patients with ischemic heart disease and an ICD and of 60 patients with nonischemic heart disease and an ICD, ventricular tachycardia and ventricular fibrillation episodes per month were not significantly different between the 2 groups [7]. At 19-month follow-up of 105 patients with ischemic cardiomyopathy and of 48 patients with nonischemic cardiomyopathy and nonsustained ventricular tachycardia, appropriate ICD shocks occurred in 50% of patients with nonischemic cardiomyopathy versus 36% of patients with ischemic cardiomyopathy (p not significant). At 33-month follow-up of 485 patients with ischemic cardiomyopathy and of 299 patients with nonischemic cardiomyopathy in the present study, the incidence of appropriate ICD shocks was 37% in patients with ischemic cardiomyopathy versus 31% in patients with nonischemic cardiomyopathy (p not significant). Unlike the other 2 studies [7, 8], there was no significant difference in baseline characteristics between patients with ischemic versus nonischemic cardiomyopathy in the present study. In other studies, appropriate ICD shocks occurred at 33-month follow-up in 329 of 1,038 patients (32%) [11], at 70-month follow-up in 421 of 1,382 patients (31%) [12], at 17-month follow-up in 169 of 719 patients (24%) in the Multicenter Automatic Defibrillator Implantation Trial II [13], at 29-month follow-up in 33 of 229 patients (14%) with nonischemic cardiomyopathy in the Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation Trial [14], and at 31-month follow-up in 52 of 140 patients (37%) with nonischemic cardiomyopathy [15]. Since the incidence of appropriate ICD shocks in the present study and in those previously reported [11-15] varied from 14% to 37%, this should be considered a limitation of the current guidelines for ICD implantation. Patients in our study with appropriate ICD shocks who died died of congestive heart failure or fatal myocardial infarction instead of sudden cardiac death. In the present study, the low use of angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (51% in patients with ischemic cardiomyopathy and 50% in patients with nonischemic cardiomyopathy) was due to low blood pressure or renal insufficiency in patients. Statins were administered to 197 of 299 patients (66%) with nonischemic cardiomyopathy because these 197 patients had dyslipidemia. Confounding factors for appropriate ICD shocks and for all-cause mortality are listed in Table I. Statistical analysis showed no significance difference in any of the confounding variables between patients with ischemic cardiomyopathy versus nonischemic cardiomyopathy. In the study by Ermis et al. [7], there were 250 patients with ICDs. Mortality was 19% in patients with ischemic cardiomyopathy versus 11% in patients with nonischemic cardiomyopathy (p value not stated). The number of patients with nonischemic cardiomyopathy versus ischemic cardiomyopathy, the follow-up time for each group, and the baseline characteristics of each group for the 250 patients are not stated [7]. In the study by Evonich et al. [8], at 19-month follow-up, 12 of 105 patients (11%) with ischemic cardiomyopathy and 2 of 48 patients with nonischemic cardiomyopathy (4%) had died (p not significant). In the present study, at 33-month follow-up, 162 of 485 patients (33%) with ischemic cardiomyopathy and 70 of 299 patients (23%) with nonischemic cardiomyopathy had died (p = 0.002). In conclusion, the present study and 2 smaller studies [7, 8] showed no significant difference in appropriate ICD shocks at follow-up between patients with ischemic cardiomyopathy and nonischemic cardiomyopathy. The present study showed a significantly higher mortality at follow-up in patients with ischemic cardiomyopathy versus nonischemic cardiomyopathy and no significant differences in baseline characteristics (p = 0.002). The small number of patients with nonischemic cardiomyopathy in the 2 other studies is a limitation for mortality data in these studies [7, 8]. Additional studies with large numbers of patients with ischemic cardiomyopathy and nonischemic cardiomyopathy with ICDs are needed to confirm our data.
  14 in total

1.  2009 focused update: ACCF/AHA Guidelines for the Diagnosis and Management of Heart Failure in Adults: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines: developed in collaboration with the International Society for Heart and Lung Transplantation.

Authors:  Mariell Jessup; William T Abraham; Donald E Casey; Arthur M Feldman; Gary S Francis; Theodore G Ganiats; Marvin A Konstam; Donna M Mancini; Peter S Rahko; Marc A Silver; Lynne Warner Stevenson; Clyde W Yancy
Journal:  Circulation       Date:  2009-03-26       Impact factor: 29.690

2.  Prevalence of appropriate cardioverter-defibrillator shocks in 1038 consecutive patients with implantable cardioverter-defibrillators.

Authors:  Adam Kruger; Wilbert S Aronow; Hoang Lai; Harit Desai; Atul Singla; William H Frishman; Martin Cohen; Carmine Sorbera
Journal:  Am J Ther       Date:  2009 Jul-Aug       Impact factor: 2.688

3.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

4.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

5.  Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators.

Authors:  A J Moss; W J Hall; D S Cannom; J P Daubert; S L Higgins; H Klein; J H Levine; S Saksena; A L Waldo; D Wilber; M W Brown; M Heo
Journal:  N Engl J Med       Date:  1996-12-26       Impact factor: 91.245

6.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

7.  A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators.

Authors:  A E Buxton; K L Lee; J D Fisher; M E Josephson; E N Prystowsky; G Hafley
Journal:  N Engl J Med       Date:  1999-12-16       Impact factor: 91.245

8.  The effect of gender on mortality or appropriate shock in patients with nonischemic cardiomyopathy who have implantable cardioverter-defibrillators.

Authors:  Henry A Chen; Henry H Hsia; Randall Vagelos; Michael Fowler; Paul Wang; Amin Al-Ahmad
Journal:  Pacing Clin Electrophysiol       Date:  2007-03       Impact factor: 1.976

9.  Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?

Authors:  Kenneth A Ellenbogen; Joseph H Levine; Ronald D Berger; James P Daubert; Stephen L Winters; Eugene Greenstein; Alaa Shalaby; Andi Schaechter; Haris Subacius; Alan Kadish
Journal:  Circulation       Date:  2006-02-06       Impact factor: 29.690

10.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.

Authors:  Alan Kadish; Alan Dyer; James P Daubert; Rebecca Quigg; N A Mark Estes; Kelley P Anderson; Hugh Calkins; David Hoch; Jeffrey Goldberger; Alaa Shalaby; William E Sanders; Andi Schaechter; Joseph H Levine
Journal:  N Engl J Med       Date:  2004-05-20       Impact factor: 91.245

View more
  3 in total

1.  Predicting appropriate shocks in patients with heart failure: Patient level meta-analysis from SCD-HeFT and MADIT II.

Authors:  Emily P Zeitler; Sana M Al-Khatib; Daniel J Friedman; Joo Yoon Han; Jeanne E Poole; Gust H Bardy; J Thomas Bigger; Alfred E Buxton; Arthur J Moss; Kerry L Lee; Paul Dorian; Riccardo Cappato; Alan H Kadish; Peter J Kudenchuk; Daniel B Mark; Lurdes Y T Inoue; Gillian D Sanders
Journal:  J Cardiovasc Electrophysiol       Date:  2017-08-23

Review 2.  Prevention of sudden cardiac death in patients with chronic kidney disease.

Authors:  Beata Franczyk-Skóra; Anna Gluba; Maciej Banach; Dariusz Kozłowski; Jolanta Małyszko; Jacek Rysz
Journal:  BMC Nephrol       Date:  2012-12-03       Impact factor: 2.388

3.  Follow-up of implantable cardioverter-defibrillator therapy: comparison of coronary artery disease and dilated cardiomyopathy.

Authors:  M P Verhagen; N van Boven; J H Ruiter; G-J P Kimman; G J Tahapary; V A Umans
Journal:  Neth Heart J       Date:  2014-10       Impact factor: 2.380

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.