The "systolic volume balance" method for the noninvasive estimation of cardiac output based on pressure wave analysis.

Theodore G Papaioannou1, Orestis Vardoulis, Nikos Stergiopulos.   

Abstract

Cardiac output (CO) monitoring is essential for the optimal management of critically ill patients. Several mathematical methods have been proposed for CO estimation based on pressure waveform analysis. Most of them depend on invasive recording of blood pressure and require repeated calibrations, and they suffer from decreased accuracy under specific conditions. A new systolic volume balance (SVB) method, including a simpler empirical form (eSVB), was derived from basic physical principles that govern blood flow and, in particular, a volume balance approach for the conservation of mass ejected into and flowed out of the arterial system during systole. The formulas were validated by a one-dimensional model of the systemic arterial tree. Comparisons of CO estimates between the proposed and previous methods were performed in terms of agreement and accuracy using "real" CO values of the model as a reference. Five hundred and seven different hemodynamic cases were simulated by altering cardiac period, arterial compliance, and resistance. CO could be accurately estimated by the SVB method as follows: CO = C × PP(ao)/(T - P(sm) × T(s)/P(m)) and by the eSVB method as follows: CO = k × C × PP(ao)/T, where C is arterial compliance, PP(ao) is aortic pulse pressure, T is cardiac period, P(sm) is mean systolic pressure, T(s) is systolic duration, P(m) is mean pressure, and k is an empirical coefficient. SVB applied on aortic pressure waves did not require calibration or empirical correction for CO estimation. An empirical coefficient was necessary for brachial pressure wave analysis. The difference of SVB-derived CO from model CO (for brachial waves) was 0.042 ± 0.341 l/min, and the limits of agreement were -0.7 to 0.6 l/min, indicating high accuracy. The intraclass correlation coefficient and root mean square error between estimated and "real" CO were 0.861 and 0.041 l/min, respectively, indicating very good accuracy. eSVB also provided accurate estimation of CO. An in vivo validation study of the proposed methods remains to be conducted.

Entities:  

Mesh:

Year:  2012        PMID: 22427512     DOI: 10.1152/ajpheart.00052.2012

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  6 in total

Review 1.  Generic and patient-specific models of the arterial tree.

Authors:  Philippe Reymond; Orestis Vardoulis; Nikos Stergiopulos
Journal:  J Clin Monit Comput       Date:  2012-07-29       Impact factor: 2.502

2.  The Optimal Haemoglobin Target in Dialysis Patients May Be Determined by Its Contrasting Effects on Arterial Stiffness and Pressure Pulsatility.

Authors:  Hon-Chun Hsu; Chanel Robinson; Gavin R Norton; Angela J Woodiwiss; Patrick H Dessein
Journal:  Int J Nephrol Renovasc Dis       Date:  2020-12-30

3.  Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes.

Authors:  Peter H Charlton; Jorge Mariscal Harana; Samuel Vennin; Ye Li; Phil Chowienczyk; Jordi Alastruey
Journal:  Am J Physiol Heart Circ Physiol       Date:  2019-08-23       Impact factor: 4.733

4.  Relationship between stroke volume and pulse pressure during blood volume perturbation: a mathematical analysis.

Authors:  Ramin Bighamian; Jin-Oh Hahn
Journal:  Biomed Res Int       Date:  2014-05-20       Impact factor: 3.411

5.  Noninvasive estimation of aortic hemodynamics and cardiac contractility using machine learning.

Authors:  Vasiliki Bikia; Theodore G Papaioannou; Stamatia Pagoulatou; Georgios Rovas; Evangelos Oikonomou; Gerasimos Siasos; Dimitris Tousoulis; Nikolaos Stergiopulos
Journal:  Sci Rep       Date:  2020-09-14       Impact factor: 4.379

Review 6.  Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet.

Authors:  Peter H Charlton; Birutė Paliakaitė; Kristjan Pilt; Martin Bachler; Serena Zanelli; Dániel Kulin; John Allen; Magid Hallab; Elisabetta Bianchini; Christopher C Mayer; Dimitrios Terentes-Printzios; Verena Dittrich; Bernhard Hametner; Dave Veerasingam; Dejan Žikić; Vaidotas Marozas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-12-24       Impact factor: 4.733

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.