Literature DB >> 22425818

Noninvasive monitoring of blood pressure in the critically ill: reliability according to the cuff site (arm, thigh, or ankle).

Karim Lakhal1, Christine Macq, Stephan Ehrmann, Thierry Boulain, Xavier Capdevila.   

Abstract

OBJECTIVE: In the critically ill, blood pressure measurements mostly rely on automated oscillometric devices pending the intra-arterial catheter insertion or after its removal. If the arms are inaccessible, the cuff is placed at the ankle or the thigh, but this common practice has never been assessed. We evaluated the reliability of noninvasive blood pressure readings at these anatomic sites.
DESIGN: Prospective observational study.
SETTING: Medical-surgical intensive care unit. PATIENTS: Patients carrying an arterial line with no severe occlusive arterial disease. INTERVENTION: Each patient underwent a set of three pairs of noninvasive and intra-arterial measurements at each site (arm, ankle, thigh [if Ramsay sedation scale >4]) and, in case of circulatory failure, a second set of measurements after a cardiovascular intervention (volume expansion, change in catecholamine dosage).
MEASUREMENTS AND MAIN RESULTS: In 150 patients, whatever the cuff site, the agreement between invasive and noninvasive readings was markedly higher for mean arterial pressure than for systolic or diastolic pressure. For mean arterial pressure measurement, arm noninvasive blood pressure was reliable (mean bias of 3.4 ± 5.0 mm Hg, lower/upper limit of agreement of -6.3/13.1 mm Hg) contrary to ankle or thigh noninvasive blood pressure (mean bias of 3.1 ± 7.7 mm Hg and 5.7 ± 6.8 mm Hg and lower/upper limits of agreement of -12.1/18.3 mm Hg and -7.7/19.2 mm Hg, respectively). During acute circulatory failure (n = 83), arm noninvasive blood pressure but also ankle and thigh noninvasive blood pressure allowed a reliable detection of 1) invasive mean arterial pressure <65 mm Hg (area under the receiver operating characteristic curve of 0.98 [0.92-1], 0.93 [0.85-0.97], and 0.93 [0.85-0.98] for arm, ankle, and thigh noninvasive blood pressure, respectively); and 2) a significant (>10%) increase in invasive mean arterial pressure after a cardiovascular intervention (area under the receiver operating characteristic curve of 0.99 [0.92-1], 0.90 [0.80-0.97], and 0.96 [0.87-0.99], respectively).
CONCLUSION: In our population, arm noninvasive mean arterial pressure readings were accurate. Either the ankle or the thigh may be reliable alternatives, only to detect hypotensive and therapy-responding patients.

Entities:  

Mesh:

Year:  2012        PMID: 22425818     DOI: 10.1097/CCM.0b013e31823dae42

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  13 in total

1.  Non-invasive blood pressure monitoring with an oscillometric brachial cuff: impact of arrhythmia.

Authors:  Karim Lakhal; Maëlle Martin; Stephan Ehrmann; Sofian Faiz; Bertrand Rozec; Thierry Boulain
Journal:  J Clin Monit Comput       Date:  2017-09-27       Impact factor: 2.502

2.  The effect of intermittent intraabdominal pressure elevations and low cardiac output on the femoral to carotid arterial blood pressure difference in piglets.

Authors:  Devrim Aksakal; Thomas Hückstädt; Steffen Richter; Daniela Klitscher; Tobias Wowra; Felix Schier; Lucas M Wessel; Rainer Kubiak
Journal:  Surg Endosc       Date:  2016-03-16       Impact factor: 4.584

3.  Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

Authors:  Ali A Saherwala; Sonja E Stutzman; Mohamed Osman; Junaid Kalia; Stephen A Figueroa; DaiWai M Olson; Venkatesh Aiyagari
Journal:  Neurocrit Care       Date:  2018-06       Impact factor: 3.210

4.  Intensive Care Medicine in 2050: toward an intensive care unit without waste.

Authors:  George L Anesi; Jason Wagner; Scott D Halpern
Journal:  Intensive Care Med       Date:  2016-12-08       Impact factor: 17.440

5.  Management of circulatory shock and hypotension.

Authors:  Kay Choong See
Journal:  Singapore Med J       Date:  2022-05       Impact factor: 3.331

6.  Variation of arterial and central venous catheter use in United States intensive care units.

Authors:  Hayley B Gershengorn; Allan Garland; Andrew Kramer; Damon C Scales; Gordon Rubenfeld; Hannah Wunsch
Journal:  Anesthesiology       Date:  2014-03       Impact factor: 7.892

7.  Relationship between Hypotension and Cerebral Ischemia during Hemodialysis.

Authors:  Clare MacEwen; Sheera Sutherland; Jonathan Daly; Christopher Pugh; Lionel Tarassenko
Journal:  J Am Soc Nephrol       Date:  2017-03-07       Impact factor: 10.121

Review 8.  Techniques for Non-Invasive Monitoring of Arterial Blood Pressure.

Authors:  Agnes S Meidert; Bernd Saugel
Journal:  Front Med (Lausanne)       Date:  2018-01-08

9.  Non-invasive monitoring of blood pressure using the Philips Intellivue MP50 monitor cannot replace invasive blood pressure techniques in surgery patients under general anesthesia.

Authors:  Xianghu Meng; Guanghui Zang; Longchang Fan; Lei Zheng; Jinzhen Dai; Xueren Wang; Wei Xia; Jihong Liu; Chuanhan Zhang
Journal:  Exp Ther Med       Date:  2013-05-17       Impact factor: 2.447

10.  Noninvasive oscillometric cardiac output determination in the intensive care unit - comparison with invasive transpulmonary thermodilution.

Authors:  Alexander Reshetnik; Friederike Compton; Anna Schölzel; Markus Tölle; Walter Zidek; Markus van der Giet
Journal:  Sci Rep       Date:  2017-08-30       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.