Literature DB >> 22424993

Optimal headrest height for the best laryngoscopic view: by anatomical measurements.

Young-Tae Jeon1, Jung-won Hwang, Kyuseok Kim, Cheol-Kyu Jung, Hee-Pyoung Park, Sang-Heon Park.   

Abstract

BACKGROUND: We hypothesized that the oro-pharyngolaryngeal axes, occipito-atlanto-axial extension (OAA) angle and intubation distance would be influenced by the height of headrests.
METHODS: Twenty patients were enrolled. The Macintosh 3 blade was used for direct laryngoscopy without a headrest or with the headrest of 6 or 12 cm high in randomized order, whereas a lateral radiograph of the neck was taken when the best laryngoscopic view was obtained. The following measurements were made: (1) the axis of the mouth (MA), the pharyngeal axis (PA), the laryngeal axis (LA), and the line of vision (LV). The various angles between these axes were defined: α angle between MA and PA, β angle between PA and LA, and δ angle between LV and LA. (2) Intubation distance, (3) mentovertebral distance, and (4) OAA angle.
RESULTS: Compared with 12-cm and no headrest, the δ angle decreased significantly with 6-cm headrest (19.4°/29.2°/29.2° in 6-cm/12-cm/no headrest, respectively; P < .001), and the intubation distance increased significantly (46.2/37.3/38.7 mm in 6-cm/12-cm/no headrest, respectively; P < .001). Mentovertebral distance was smallest (107.0/106.7/98.5 mm; P < .05) at 12-cm headrest. Occipito-atlanto-axial extension angle was largest significantly (40.7°/35.2°/34.5°; P < .05) at 6-cm headrest.
CONCLUSION: We conclude that compared with no or 12-cm headrest, 6-cm headrest could facilitate more alignment of these axes, increase the OAA angle, and enlarge the intubation distance. Crown
Copyright © 2012. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22424993     DOI: 10.1016/j.ajem.2012.01.016

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  2 in total

1.  Hemodynamic effects of topical lidocaine on the laryngoscope blade and trachea during endotracheal intubation: a prospective, double-blind, randomized study.

Authors:  Sue-Young Lee; Jeong Jin Min; Hyun Joo Kim; Deok Man Hong; Hyun-Jung Kim; Hee-Pyoung Park
Journal:  J Anesth       Date:  2014-03-12       Impact factor: 2.078

2.  A randomised comparative study on customised versus fixed sized pillow for tracheal intubation in the sniffing position by Macintosh laryngoscopy.

Authors:  Mridul Dhar; Habib Md Reazaul Karim; Narayanan Rajaram; Avinash Prakash; Sarasa K Sahoo; Anilkumar Narayan
Journal:  Indian J Anaesth       Date:  2018-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.