BACKGROUND: Effective diagnosis of malaria is a major component of case management. Rapid diagnostic tests (RDTs) based on Plasmodium falciparumhistidine-rich protein 2 (PfHRP2) are popular for diagnosis of this most virulent malaria infection. However, concerns have been raised about the longevity of the PfHRP2 antigenaemia following curative treatment in endemic regions.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22423618 PMCID: PMC3359291 DOI: 10.1186/1475-2875-11-74
Source DB: PubMed Journal: Malar J ISSN: 1475-2875 Impact factor: 2.979
Optimal multiplication factor for production of PfHRP2 by 3D7 P.falciparum parasites
| Subject | Treatment day | No. pre-treatment data points | Optimal multiplication factor ( | Estimated |
|---|---|---|---|---|
| 12 | 7.5 | 4 | 24.4 | 127 fg |
| 13 | 7.5 | 3 | 17.5 | 91 fg |
| 14 | 9.5 | 6 | 39.4 | 205 fg |
The estimated quantity of PfHRP2 produced per parasite is calculated as m x 5.2 fg.
Figure 1Parasitaemia and ELISA data from Study 1, along with the predicted. Data are presented for a) Patient 12, b) Patient 13 and c) Patient 14. The PfHRP2 concentrations were predicted by applying the fitted model with the mean optimal PfHRP2 production of 1.4 × 10-13 g per parasite per replication cycle.
Figure 2Parasitaemia and estimated. Data are presented for patients a) S561, b) S707 and c) S811 in Study 2. Predicted PfHRP2 concentrations are for the maximum (H) and minimum (H) circulating PfHRP2, and the PfHRP2 concentration which would be measured during and ELISA or RDT (Tand T) which includes intracellular PfHRP2 which is released during the assay.
Characteristics of predicted PfHRP2 kinetics in illustrative untreated infections
| Patient | Day of first fever | Fitted model | Unadjusted model | |||
|---|---|---|---|---|---|---|
| First day above threshold (MinCM, MaxCM) | Days above threshold (range) | First day above threshold (MinCM, MaxCM) | Days above threshold (range) | |||
| S561 | 2 | 100 | 2,2 | 32-34 | 4,3 | 9-15 |
| 20 | 2,2 | 39-46 | 2,2 | 19-25 | ||
| 10 | 2,2 | 44-51 | 2,2 | 24-31 | ||
| S707 | 4 | 100 | 2,2 | 25-29 | 7,5 | 2-6 |
| 20 | 2,2 | 31-35 | 5,5 | 10-15 | ||
| 10 | 2,1 | 34-40 | 5,3 | 13-25 | ||
| S811 | 2 | 100 | 2,2 | 50-56 | 4,4 | 2-7 |
| 20 | 2,2 | 59-64 | 4,2 | 21-31 | ||
| 10 | 2,2 | 63-68 | 2,2 | 29-47 | ||
The kinetics are summarized by the day they first exceed a nominated threshold under the minimum (MinCM) and maximum circulating PfHRP2 models (MaxCM) and the total number of days they are above this threshold. A range for the number of days above the threshold is given by combining the results from the MinCM and MaxCM models. Results are presented using the mean PfHRP2 production fitted in this study (fitted model) and also the previously reported PfHRP2 production of 5.2 fg/parasite/replication cycle (unadjusted model) [8].
Figure 3Predicted minimum number of. Data are presented for the fitted maximum circulating model (T, red) and minimum circulating model (T, blue).
Malaria RDT reactivity againstP.falciparumculture supernatant
| Product | Intensity of | ||||||
|---|---|---|---|---|---|---|---|
| 27.75 ng/mL | 13.88 ng/mL | 6.94 ng/mL | 3.47 ng/mL | 1.73 ng/mL | 0.87 ng/mL | 0 ng/mL (-ve control) | |
| Firstsign™ - ParaView (Pan + Pf) Malaria Test | 1 | Neg | Neg | Neg | Neg | Neg | Neg |
| SD BIOLINE Malaria Ag Pf/Pv | 4 | 2 | 1 | Neg | Neg | Neg | Neg |
| Carestart™ Malaria HRP2/pLDH | 1 | 1 | 1 | Neg | Neg | Neg | Neg |
| ICT Malaria Combo Cassette Test | 4 | 2 | 1 | 1 | 1 | 1 | 1 |
Table entries are the intensities of the PfHRP2 band, scored from 1 (faint band) to 4 (strong band). Neg indicates no PfHRP2 band was visible.
Predicted equilibrium parasite densities required to maintain a positive RDT test
| Product | Min. detectable | Est. no. parasites for MinCM (parasites/μL) | Est. no. parasites for MaxCM (parasites/μL) |
|---|---|---|---|
| Firstsign™ - ParaView (Pan + Pf) Malaria Test | 27.75 | 64.9 | 29.6 |
| SD BIOLINE Malaria Ag Pf/Pv | 6.94 | 16.7 | 7.8 |
| Carestart™ Malaria HRP2/pLDH | 6.94 | 16.7 | 7.8 |
| ICT Malaria Combo Cassette Test | 13.88* | 32.8 | 15.1 |
* The lowest dilution which gives a band intensity > 1 to adjust for false positive result on negative control.
MinCM and MaxCM represent the minimum circulating model and maximum circulating model, respectively.