Literature DB >> 22422805

Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties.

Sonali Natu1, Raghavendra Prasad Sidaginamale, Jamshid Gandhi, David J Langton, Antoni V F Nargol.   

Abstract

AIM: To describe the histopathology of localised adverse reactions to metal debris (ARMD) seen in association with failed metal on metal (MoM) hip arthroplasties. The nature of aseptic lymphocytic vasculitis associated lesion (ALVAL) is investigated.
METHODS: Periprosthetic soft tissues biopsied at time of revision from failed MoM hip arthroplasties from January 2007 to March 2011 were analysed. The inflammatory cell response was categorised into perivascular lymphocytic cuffing (ALVAL), lymphoid aggregate formation with or without germinal centres, metallosis characterised by sheets of macrophages with intracytoplasmic metallic debris and well-defined granulomas.
RESULTS: 123 patient samples were analysed, 36 males (29.2%) and 87 females (70.8%). Three cases showing complete tissue necrosis were excluded. Patients were reviewed between 3.27 to 69.6 months postarthroplasty, with an average of 30.92 months. 103 cases (85.8%) showed ALVAL, 18 cases also showed well-defined granulomas. Of the 103 cases with ALVAL, 60 cases also showed a diffuse chronic lymphocytic synovitis, and 40 cases showed lymphoid aggregates with germinal centres. 17 cases (14.2%) showed pure metallosis. Small vessels showing ALVAL expressed peripheral node addressin.
CONCLUSIONS: ARMD is a spectrum of changes comprising of pure metallosis, ALVAL and granulomatous inflammation. ALVAL, a distinctive inflammatory response seen in ARMD, is a precursor of lymphoid neogenesis. Lymphoid neogenesis documented in a variety of chronic inflammatory conditions most probably contributes to tissue necrosis and prosthetic failure seen in MoM hip arthroplasties. The role of vascular changes in contributing to necrosis is unclear at this stage.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22422805     DOI: 10.1136/jclinpath-2011-200398

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  61 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  Multivariate use of MRI biomarkers to classify histologically confirmed necrosis in symptomatic total hip arthroplasty.

Authors:  Mohammad Sherafati; Thomas W Bauer; Hollis G Potter; Matthew F Koff; Kevin M Koch
Journal:  J Orthop Res       Date:  2020-03-23       Impact factor: 3.494

3.  Metal-on-metal hip prostheses: correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream.

Authors:  Dalila De Pasquale; Susanna Stea; Stefano Squarzoni; Barbara Bordini; Marilina Amabile; Simona Catalani; Pietro Apostoli; Aldo Toni
Journal:  Int Orthop       Date:  2014-03       Impact factor: 3.075

4.  'Pseudotumour' invading the proximal femur with normal metal ions following metal on metal hip resurfacing.

Authors:  Harry Krishnan; Kapil Sugand; Ibrahim Ali; Jay Smith
Journal:  BMJ Case Rep       Date:  2015-02-10

Review 5.  Biological response to prosthetic debris.

Authors:  Diana Bitar; Javad Parvizi
Journal:  World J Orthop       Date:  2015-03-18

6.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

7.  Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces.

Authors:  Jeremy L Gilbert; Shiril Sivan; Yangping Liu; Sevi B Kocagöz; Christina M Arnholt; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2014-03-26       Impact factor: 4.396

8.  CORR Insights®: Current Pathologic Scoring Systems for Metal-on-metal THA Revisions are not Reproducible.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2017-09-27       Impact factor: 4.176

Review 9.  Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates.

Authors:  S Sehatzadeh; K Kaulback; L Levin
Journal:  Ont Health Technol Assess Ser       Date:  2012-08-01

10.  601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.

Authors:  Amit Atrey; Alister Hart; Nasir Hussain; Jonathon Waite; Andrew J Shepherd; Steve Young
Journal:  J Orthop       Date:  2016-10-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.