CT fluoroscopy-guided vertebral augmentation with a radiofrequency-induced, high-viscosity bone cement (StabiliT(®)): technical results and polymethylmethacrylate leakages in 25 patients.

Christoph Gregor Trumm1, Tobias F Jakobs, Robert Stahl, Torleif A Sandner, Philipp M Paprottka, Maximilian F Reiser, Christoph J Zech, Ralf-Thorsten Hoffmann.   

Abstract

OBJECTIVE: To assess the technical results of CT fluoroscopy-guided, radiofrequency-induced vertebral augmentation (StabiliT®) in terms of vertebral height restoration and polymethylmethacrylate (PMMA) leakages, occurring in 25 individual patients with vertebral compression fractures and osteolysis.
MATERIALS AND METHODS: From 07/2010 to 08/2011, 25 patients (16 women, nine men; age 71 ± 14; range 41-89) with painful vertebral compression fractures due to osteoporosis (n = 19), metastases (n = 2) or multiple myeloma (n = 4) underwent vertebral augmentation with a radiofrequency-activated, high-viscosity polymethylmethacrylate (PMMA) bone cement (StabiliT® Vertebral Augmentation system; DFINE Europe GmbH, Mannheim) under local anesthesia. Thirty-four vertebrae (Th5-L5) were treated in 27 sessions under CT fluoroscopy guidance (128-row CT, Somatom Definition AS, Siemens, Erlangen) using a unilateral access and a cavity-creating osteotome prior to remote-controlled, hydraulically driven cement injection. 1/2/3 levels were treated in 21/5/1 session(s). Vertebral height change in the midsagittal plane (anterior, midvertebral, posterior endplate distance) and PMMA leaks were retrospectively evaluated using the postinterventional CT.
RESULTS: All patients were successfully treated in the first session. Mean (MV ± SD) procedure time and amount of injected PMMA were 56 ± 14 min and 4.5 ± 1.4 ml, respectively. Mean anterior/midvertebral/posterior height gain was +7.1/+9.7/+0.4%. Small local vertebral leaks were observed in 18/34 vertebrae (53%) without any clinical sequelae. No major complications occurred.
CONCLUSIONS: CT fluoroscopy-guided, RF-induced vertebral augmentation with a high-viscosity bone cement (StabiliT®) was safe and technically successful in all patients. Using a hydraulic cement injection technique, a moderate restoration of anterior and midvertebral height was seen while the system was not markedly superior to standard vertebroplasty regarding the frequency of minor asymptomatic PMMA leaks.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22422022     DOI: 10.1007/s00256-012-1386-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  23 in total

1.  Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate : a case report.

Authors:  K D Harrington
Journal:  J Bone Joint Surg Am       Date:  2001-07       Impact factor: 5.284

2.  [DFine radiofrequency kyphoplasty (RFK)--kyphoplasty with ultrahigh viscosity cement].

Authors:  F A Elgeti; T Marnitz; T J Kröncke; B Gebauer
Journal:  Rofo       Date:  2010-04-27

3.  Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures.

Authors:  Giovanni Carlo Anselmetti; Gregg Zoarski; Antonio Manca; Salvatore Masala; Haris Eminefendic; Filippo Russo; Daniele Regge
Journal:  Cardiovasc Intervent Radiol       Date:  2008-04-04       Impact factor: 2.740

4.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

5.  An evaluation of fracture stabilization comparing kyphoplasty and titanium mesh repair techniques for vertebral compression fractures: is bone cement necessary?

Authors:  Hossein Ghofrani; Thomas Nunn; Claire Robertson; Andrew Mahar; Yupo Lee; Steven Garfin
Journal:  Spine (Phila Pa 1976)       Date:  2010-07-15       Impact factor: 3.468

6.  Synthesis and characterization of polymeric implant for kyphoplasty.

Authors:  Boaz Mizrahi; Ronen Shavit; Abraham Domb
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-08       Impact factor: 3.368

7.  Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty.

Authors:  Robert Rotter; Heiner Martin; Sebastian Fuerderer; Michael Gabl; Christoph Roeder; Paul Heini; Thomas Mittlmeier
Journal:  Eur Spine J       Date:  2010-03-01       Impact factor: 3.134

8.  Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.

Authors:  Vidyadhar V Upasani; Claire Robertson; Deborah Lee; Tucker Tomlinson; Andrew T Mahar
Journal:  Spine (Phila Pa 1976)       Date:  2010-09-01       Impact factor: 3.468

9.  The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis.

Authors:  Anne Polikeit; Lutz Peter Nolte; Stephen J Ferguson
Journal:  Spine (Phila Pa 1976)       Date:  2003-05-15       Impact factor: 3.468

10.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

View more
  7 in total

1.  [Computed tomography guidance: fluoroscopy and more].

Authors:  P M Paprottka; T Helmberger; M F Reiser; C G Trumm
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

2.  Outcome of long-axis percutaneous sacroplasty for the treatment of sacral insufficiency fractures with a radiofrequency-induced, high-viscosity bone cement.

Authors:  Katrin Eichler; Stephan Zangos; Martin G Mack; Ingo Marzi; Thomas J Vogl
Journal:  Skeletal Radiol       Date:  2014-01-23       Impact factor: 2.199

Review 3.  Benign Spine Lesions: Advances in Techniques for Minimally Invasive Percutaneous Treatment.

Authors:  A Tomasian; A N Wallace; J W Jennings
Journal:  AJNR Am J Neuroradiol       Date:  2017-02-09       Impact factor: 3.825

Review 4.  What's new in vertebral cementoplasty?

Authors:  Mario Muto; Gianluigi Guarnieri; Francesco Giurazza; Luigi Manfrè
Journal:  Br J Radiol       Date:  2016-01-05       Impact factor: 3.039

Review 5.  Current trends in mini-invasive management of spine metastases.

Authors:  Gianluigi Guarnieri; Roberto Izzo; Mario Muto
Journal:  Interv Neuroradiol       Date:  2015-05-11       Impact factor: 1.610

Review 6.  Interventional Radiology in the Management of Metastases and Bone Tumors.

Authors:  Ferruccio Sgalambro; Luigi Zugaro; Federico Bruno; Pierpaolo Palumbo; Nicola Salducca; Carmine Zoccali; Antonio Barile; Carlo Masciocchi; Francesco Arrigoni
Journal:  J Clin Med       Date:  2022-06-07       Impact factor: 4.964

7.  Prospective single-site experience with radiofrequency-targeted vertebral augmentation for osteoporotic vertebral compression fracture.

Authors:  Franklin G Moser; Marcel M Maya; Laura Blaszkiewicz; Andrea Scicli; Larry E Miller; Jon E Block
Journal:  J Osteoporos       Date:  2013-10-20
  7 in total