Literature DB >> 22421268

Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women.

Julie A Ray1, Mark M Kushnir, Ashley Bunker, Alan L Rockwood, A Wayne Meikle.   

Abstract

BACKGROUND: Measurement of free estradiol offers a better representation of the bioactive fraction of the hormone. We describe a direct equilibrium dialysis-liquid chromatography-tandem mass spectrometry (ED-LC-MS/MS) method for serum free estradiol.
METHODS: Two hundred fifty microliter aliquots of serum were dialyzed for 22h followed by liquid-liquid extraction and derivatization with dansyl chloride. Free estradiol was measured using LC-MS/MS with an AB SCIEX 5500 mass spectrometer in positive ion and multiple reaction monitoring (MRM) mode.
RESULTS: The limits of detection and quantification for free estradiol were 0.25 and 0.5pg/ml (0.9 and 1.8pmol/l) respectively. Total imprecision was less than 10%. Results of method comparison showed 3 times overestimation using indirect methods of measurement. Reference intervals in pre-menopausal women in follicular, mid-cycle, and luteal phases of cycle were <2.4, <3.1 and <2.6pg/ml (8.8, 11.4, 9.5pmol/l) respectively; in post menopausal women the concentrations were ≤0.5pg/ml (1.8pmol/l).
CONCLUSIONS: ED-LC-MS/MS is a direct method for accurately measuring free estradiol, independent of total estradiol or sex hormone binding globulin concentrations. Imprecision and sensitivity of the method are adequate for clinical diagnostic applications. The degree of variation observed in the method comparison reinforces the relevance of method specific reference ranges.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22421268     DOI: 10.1016/j.cca.2012.02.028

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  6 in total

1.  Measurement of estradiol, estrone, and testosterone in postmenopausal human serum by isotope dilution liquid chromatography tandem mass spectrometry without derivatization.

Authors:  Kerry M Wooding; Joseph A Hankin; Chris A Johnson; Justin D Chosich; Sung W Baek; Andrew P Bradford; Robert C Murphy; Nanette Santoro
Journal:  Steroids       Date:  2015-01-21       Impact factor: 2.668

2.  Surface Functionalized Magnetic Nanoparticles as a Selective Sorbent for Affinity Fishing of PPAR-γ Ligands from Choerospondias axillaris.

Authors:  Miaomiao Chi; Kunming Qin; Lei Cao; Min Zhang; Yingying Su; Xun Gao
Journal:  Molecules       Date:  2022-05-13       Impact factor: 4.927

3.  Energy-containing beverages: reproductive hormones and ovarian function in the BioCycle Study.

Authors:  Karen C Schliep; Enrique F Schisterman; Sunni L Mumford; Anna Z Pollack; Neil J Perkins; Aijun Ye; Cuilin J Zhang; Joseph B Stanford; Christina A Porucznik; Ahmad O Hammoud; Jean Wactawski-Wende
Journal:  Am J Clin Nutr       Date:  2013-01-30       Impact factor: 7.045

Review 4.  Vitamin D Binding Protein and the Biological Activity of Vitamin D.

Authors:  Rene F Chun; Albert Shieh; Carter Gottlieb; Vahe Yacoubian; Jeffrey Wang; Martin Hewison; John S Adams
Journal:  Front Endocrinol (Lausanne)       Date:  2019-10-24       Impact factor: 6.055

5.  Sex-specific Estrogen Levels and Reference Intervals from Infancy to Late Adulthood Determined by LC-MS/MS.

Authors:  Hanne Frederiksen; Trine Holm Johannsen; Stine Ehlern Andersen; Jakob Albrethsen; Selma Kløve Landersoe; Jørgen Holm Petersen; Anders Nyboe Andersen; Esben Thyssen Vestergaard; Mia Elbek Schorring; Allan Linneberg; Katharina M Main; Anna-Maria Andersson; Anders Juul
Journal:  J Clin Endocrinol Metab       Date:  2020-03-01       Impact factor: 5.958

6.  Systemic estradiol levels with low-dose vaginal estrogens.

Authors:  Richard J Santen; Sebastian Mirkin; Brian Bernick; Ginger D Constantine
Journal:  Menopause       Date:  2020-03       Impact factor: 3.310

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.