Literature DB >> 22419062

An effective intra-operative neurophysiological monitoring scheme for aneurysm clipping and spinal fusion surgeries.

Mohammed Goryawala1, Ilker Yaylali, Mercedes Cabrerizo, Krishnatej Vedala, Malek Adjouadi.   

Abstract

Somatosensory-evoked potentials (SSEPs) have been widely used for intra-operative neurophysiological monitoring (IONM). Currently at least 200-300 trials are required to generate a readable SSEP signal. This study introduces a novel approach that yields accurate detection results of the SSEP signal yet with a significantly reduced number of trials, resulting in an effectual monitoring process. The analysis was performed on data recorded in seven patients undergoing surgery, where the posterior tibial nerve was stimulated and the SSEP response was recorded from scalp electroencephalography using two bipolar electrodes, C(3)-C(4) and C(Z)-F(Z). The proposed approach employs an innovative, simple yet effective algorithm based on a patient-specific Gaussian template to detect the SSEP using only 30 trials. The time latencies of the P37 and N45 peaks are detected along with the peak-to-peak amplitudes. The time latencies are detected with a mean accuracy greater than 95%. Also, the P37 and N45 peak latencies and the peak-to-peak amplitude were found to be consistent throughout the surgical procedure within the 10% and 50% acceptable clinical limits, respectively. The results obtained support the assertion that the algorithm is capable of detecting SSEPs with high accuracy and consistency throughout the entire surgical procedure using only 30 trials.

Entities:  

Mesh:

Year:  2012        PMID: 22419062     DOI: 10.1088/1741-2560/9/2/026021

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  4 in total

1.  Detection of acute femoral artery ischemia during neuroembolization by somatosensory and motor evoked potential monitoring.

Authors:  David Purger; Abdullah H Feroze; Omar Choudhri; Leslie Lee; Jaime Lopez; Robert L Dodd
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

2.  A new measure for monitoring intraoperative somatosensory evoked potentials.

Authors:  Seung-Hyun Jin; Chun Kee Chung; Jeong Eun Kim; Young Doo Choi
Journal:  J Korean Neurosurg Soc       Date:  2014-12-31

3.  Electroretinography during embolization of an ophthalmic arteriovenous fistula.

Authors:  David J Padalino; Vladyslav Melnyk; Geoffrey Allott; Eric M Deshaies
Journal:  Surg Neurol Int       Date:  2013-03-28

4.  Quasi-stationarity of EEG for intraoperative monitoring during spinal surgeries.

Authors:  Krishnatej Vedala; S M Amin Motahari; Mohammed Goryawala; Mercedes Cabrerizo; Ilker Yaylali; Malek Adjouadi
Journal:  ScientificWorldJournal       Date:  2014-02-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.