The addition of a membrane oxygenator to a ventricular assist device in a patient with acute respiratory distress syndrome.

Peter Betit1, Gregory S Matte, Robert Howe, Peter Iudiciani, Cindy Barrett, Ravi Thiagarajan, Francis Fynn-Thompson.   

Abstract

A 12-year-old boy with Marfan's syndrome required a biventricular assist device (VAD) after an aortic root replacement. The patient developed acute respiratory distress syndrome and required escalating ventilator support. We hypothesized that the addition of a membrane oxygenator in series with the assist device would improve gas exchange and allow for a more lung-protective ventilator approach. A membrane oxygenator was placed in series with the right VAD resulting in a blood path of right atrium to VAD to oxygenator to pulmonary artery. Circuit function was gauged by monitoring flow and oxygenator pressures and periodic circuit inspections and oxygenator blood gases. Heparin was titrated to maintain unfractionated antifactor Xa levels of .3-.7 IU/mL and partial thromboplastin time of 60-80 seconds. The initial sweep gas supplying the oxygenator was 5 L/min at an F1O2 of 1.0, which achieved a pH > 7.40 and a PF ratio > 250. The pre- and post-oxygenator pressures were 55-60 mmHg and 45-50 mmHg, respectively, and the measured flow at the oxygenator outlet was 2.0-2.2 L/min. The patient was changed from high-frequency oscillatory ventilation to pressure-controlled synchronized intermittent ventilation with pH maintained at 7.35-7.40 and PF ratio > 250. Paralytics were discontinued and the patient's neurologic condition was deemed intact. The patient hemorrhaged after a sternal closure and required transfusions and antifibrinolytics that led to thrombus in the membrane and membrane circuitry, which were replaced without incident. The patient's respiratory status remained stable; however, his overall condition worsened as a result of additional organ dysfunction and septicemia, and he did not survive. The addition of a membrane oxygenator to a VAD is feasible and supplements gas exchange permitting the use of more lung protective ventilation.

Entities:  

Mesh:

Year:  2011        PMID: 22416609      PMCID: PMC4557432     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  8 in total

1.  Poly-methyl pentene oxygenators have improved gas exchange capability and reduced transfusion requirements in adult extracorporeal membrane oxygenation.

Authors:  Espeed Khoshbin; Neil Roberts; Chris Harvey; David Machin; Hilliary Killer; Giles J Peek; Andrzej W Sosnowski; Richard K Firmin
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

2.  Evolution of the extracorporeal life support circuitry.

Authors:  David Palanzo; Feng Qiu; Larry Baer; J Brian Clark; John L Myers; Akif Undar
Journal:  Artif Organs       Date:  2010-11       Impact factor: 3.094

3.  Ventricular assist device application with the intermediate use of a membrane oxygenator as a bridge to pediatric heart transplantation.

Authors:  Luis Garcia-Guereta; Javier Cabo; Pedro de la Oliva; Miguel Angel Villar; Lucia Deiros Bronte; Luis Goldman; Michael Hübler
Journal:  J Heart Lung Transplant       Date:  2009-07       Impact factor: 10.247

Review 4.  Advances in extracorporeal ventilation.

Authors:  Anna Meyer; Martin Strüber; Stefan Fischer
Journal:  Anesthesiol Clin       Date:  2008-06

5.  Primary use of the venovenous approach for extracorporeal membrane oxygenation in pediatric acute respiratory failure.

Authors:  Robert Pettignano; James D Fortenberry; Micheal L Heard; Michele D Labuz; Kenneth C Kesser; April J Tanner; Scott F Wagoner; Judith Heggen
Journal:  Pediatr Crit Care Med       Date:  2003-07       Impact factor: 3.624

6.  Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO.

Authors:  S Horton; C Thuys; M Bennett; S Augustin; M Rosenberg; C Brizard
Journal:  Perfusion       Date:  2004-01       Impact factor: 1.972

7.  Bridge to lung transplantation with the novel pumpless interventional lung assist device NovaLung.

Authors:  Stefan Fischer; Andre R Simon; Tobias Welte; Marius M Hoeper; Anna Meyer; Rene Tessmann; Bernhard Gohrbandt; Jens Gottlieb; Axel Haverich; Martin Strueber
Journal:  J Thorac Cardiovasc Surg       Date:  2006-03       Impact factor: 5.209

Review 8.  Extracorporeal membrane oxygenation: quo vadis?

Authors:  Peter Betit
Journal:  Respir Care       Date:  2009-07       Impact factor: 2.258

  8 in total
  3 in total

1.  Long-term membrane oxygenator use to support an infant with acute respiratory distress syndrome on biventricular assist device.

Authors:  Hayden J Zaccagni; Joseph G Timpa; Lawrence C O'Meara; Jeffrey A Alten
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-09

Review 2.  Paracorporeal Lung Devices: Thinking Outside the Box.

Authors:  Timothy M Maul; Jennifer S Nelson; Peter D Wearden
Journal:  Front Pediatr       Date:  2018-09-05       Impact factor: 3.418

3.  Extracorporeal Membrane Oxygenation Resource Planning in the Setting of Pandemic Respiratory Illness.

Authors:  Raghu Seethala; Steven P Keller
Journal:  Ann Am Thorac Soc       Date:  2020-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.