Literature DB >> 22416112

Initial experience with distal guide catheter placement in the treatment of cerebrovascular disease: clinical safety and efficacy.

Aquilla Turk1, Muhammad Usman Manzoor, Eric MacKenzie Nyberg, Raymond D Turner, Imran Chaudry.   

Abstract

BACKGROUND: Advancements in technology have created a current generation of guide catheters that not only provide stable access but also allow navigation of tortuous portions of the carotid siphon facilitating more distal access. Clinical experience since the release of the current generation of guide catheters was reviewed to determine their safety and efficacy.
METHODS: Between October 2007 and November 2011, all neurointerventional procedures requiring access to the intracranial arterial circulation performed at our institution were reviewed. Clinical performance and complication rates of current generation guide catheters were compared with conventional guide catheters.
RESULTS: 1188 neurointerventional procedures were performed, of which 659 were eligible for this study. When navigating the anterior circulation, intracranial purchase was achieved significantly more often with current generation 0.070 inch and 0.053 inch guide catheters compared with conventional guide catheters. Similarly, current generation 0.070 inch and 0.053 inch catheters navigated at least one sharp 90° turn significantly more often than conventional guide catheters. Guide catheter related complications were encountered in 1.4% of cases with both catheter generations and differences were not significant although more complications were found when guide catheter tip position was cervical rather than intracranial.
CONCLUSION: Current generation guide catheters allow distal access with a high rate of success while maintaining a low rate of complications. When intracranial location of the guide catheter was obtained, fewer complications occurred.

Entities:  

Mesh:

Year:  2012        PMID: 22416112     DOI: 10.1136/neurintsurg-2011-010256

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  10 in total

1.  Reply.

Authors:  S R Satti; L Leishangthem; T Sivapatham
Journal:  AJNR Am J Neuroradiol       Date:  2015-12-17       Impact factor: 3.825

2.  Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion.

Authors:  Geoffrey P Colby; Li-Mei Lin; Risheng Xu; Narlin Beaty; Matthew T Bender; Bowen Jiang; Judy Huang; Rafael J Tamargo; Alexander L Coon
Journal:  Interv Neurol       Date:  2017-02-03

3.  Biaxial system using the Benchmark intracranial guide catheter for placement of a Pipeline Embolization Device for intracranial aneurysms.

Authors:  Apar S Patel; Christoph J Griessenauer; Christopher S Ogilvy; Ajith J Thomas
Journal:  Interv Neuroradiol       Date:  2016-02-22       Impact factor: 1.610

4.  Navien catheter experience in neuroendovascular interventions.

Authors:  Gaurav Jindal; Luciano Giacon; Moronke Iyoha; Timothy Miller; Francois Aldrich; Marc Simard; Ravishankar Shivashankar; Dheeraj Gandhi
Journal:  Interv Neuroradiol       Date:  2017-07-04       Impact factor: 1.610

5.  Pipeline embolization device deployment via an envoy distal access XB guiding catheter-biaxial platform: A technical note.

Authors:  Fawaz Al-Mufti; Krishna Amuluru; Inder Paul Singh; Chirag Gandhi; Charles J Prestigiacomo
Journal:  Interv Neuroradiol       Date:  2016-01-14       Impact factor: 1.610

6.  Distal access using hyperflexible atraumatic distal tip with optimized proximal stability of the Benchmark intracranial guide catheter for the treatment of cerebral vascular diseases: a technical note.

Authors:  Arun Chandran; Mani Puthuran; Paul R Eldridge; Hans C Nahser
Journal:  J Neurointerv Surg       Date:  2015-06-12       Impact factor: 5.836

7.  Preliminary experience of stent-assisted coiling of wide-necked intracranial aneurysms with a single microcatheter.

Authors:  Keun Young Park; Chang Ki Jang; Jae Whan Lee; Dong Joon Kim; Byung Moon Kim; Joonho Chung
Journal:  BMC Neurol       Date:  2019-10-22       Impact factor: 2.474

8.  Clinical Experience of Using an 8 French Newton Shaped Catheter (Neuro-EBU) During Endovascular Treatment: A Case Series of 21 Patients.

Authors:  Kazushi Maeda; Yosuke Kawano; Yoshio Suyama; Satoru Kawarazaki; Kohei Irie; Kazuhisa Kuwabara; Shintaro Nagaoka; Hidefuku Gi; Yukihide Kanemoto
Journal:  Cureus       Date:  2022-06-17

9.  47 Consecutive Cases of Pipeline Flex Flow Diversion Utilizing a Novel Large-Bore Intracranial Intermediate Catheter: Nuances and Institutional Experience with the Syphontrak.

Authors:  Li-Mei Lin; Bowen Jiang; Matthew T Bender; Erick M Westbroek; Jessica K Campos; Rafael J Tamargo; Judy Huang; Alexander L Coon; Geoffrey P Colby
Journal:  Interv Neurol       Date:  2018-02-06

10.  Advantages and disadvantages of the ENVOY 6F distal access guiding catheter in endovascular coiling for anterior circulation aneurysms.

Authors:  Jin Wook Baek; Sung-Chul Jin; Sung-Tae Kim; Young Jin Heo; Ji Yeon Han; Jung Hwa Seo; Sung Hwa Paeng; Jung Soo Kim; Hae Woong Jeong; Young-Gyun Jeong
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2019-03-31
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.