Literature DB >> 22415543

Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography.

Salvatore Brugaletta1, Hector M Garcia-Garcia, Josep Gomez-Lara, Maria D Radu, Ravindra Pawar, Jamal Khachabi, Nico Bruining, Manel Sabaté, Patrick W Serruys.   

Abstract

Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreements has not yet been evaluated. Aim of our study was therefore to evaluate the agreements of this approach, taking into account various zoom settings. 126 struts from 10 selected frames were independently evaluated by four observers using a stepwise approach increasing the zoom setting as following: (1) full view of the lumen (FV), (2) half view of the lumen (HV) and (3) a quarter view of the lumen (QV). Intra- and inter-observer agreements (κ) were assessed. The rate of uncoverage was determined for each strut as the number of times it was defined as uncovered divided by the total number of observations (maximum 12 = 3 zoom settings × 4 analysts) and expressed as percentage. The inter-observer κ values (mean [range]) were 0.32 [0.07-0.63], 0.40 [0.18-0.69] and 0.33 [0.09-0.6], within FV, HV and QV respectively. The intra-observer κ values were 0.60 [0.50-0.70], 0.75 [0.75-0.76] and 0.60 [0.50-0.70], within FV, HV and QV respectively. By increasing zoom setting the κ value of intra-observer agreement was 0.74 [0.58-0.83] (from FV to HV), 0.70 [0.56-0.83] (from HV to QV) and 0.70 [0.37-0.86] (from FV to QV). Overall, the rate of uncoverage was 15.5% [8.3-100%]. The OCT qualitative evaluation of strut coverage has wide inter and intra-observer agreements and is dependent of the zoom setting used during the analysis. A more reproducible approach would be needed to eventually increase the probability to link uncovered struts with clinical events.

Entities:  

Mesh:

Year:  2012        PMID: 22415543      PMCID: PMC3550704          DOI: 10.1007/s10554-012-0030-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  15 in total

1.  Evaluation of intracoronary stenting by intravascular optical coherence tomography.

Authors:  B E Bouma; G J Tearney; H Yabushita; M Shishkov; C R Kauffman; D DeJoseph Gauthier; B D MacNeill; S L Houser; H T Aretz; E F Halpern; I-K Jang
Journal:  Heart       Date:  2003-03       Impact factor: 5.994

Review 2.  Optical coherence tomography: clinical applications and the evaluation of DES.

Authors:  N Gonzalo; P W Serruys; E Regar
Journal:  Minerva Cardioangiol       Date:  2008-10       Impact factor: 1.347

3.  Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation.

Authors:  Yong Xie; Masamichi Takano; Daisuke Murakami; Masanori Yamamoto; Kentaro Okamatsu; Shigenobu Inami; Koji Seimiya; Takayoshi Ohba; Yoshihiko Seino; Kyoichi Mizuno
Journal:  Am J Cardiol       Date:  2008-04-25       Impact factor: 2.778

4.  Reproducibility of quantitative optical coherence tomography for stent analysis.

Authors:  Nieves Gonzalo; Hector M Garcia-Garcia; Patrick W Serruys; Koen H Commissaris; Hiram Bezerra; Pierre Gobbens; Marco Costa; Evelyn Regar
Journal:  EuroIntervention       Date:  2009-06       Impact factor: 6.534

5.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

6.  Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation.

Authors:  Akira Murata; David Wallace-Bradley; Armando Tellez; Carlos Alviar; Michael Aboodi; Alexander Sheehy; Leslie Coleman; Laura Perkins; Gaku Nakazawa; Gary Mintz; Greg L Kaluza; Renu Virmani; Juan F Granada
Journal:  JACC Cardiovasc Imaging       Date:  2010-01-12

7.  Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization.

Authors:  Aloke V Finn; Michael Joner; Gaku Nakazawa; Frank Kolodgie; John Newell; Mike C John; Herman K Gold; Renu Virmani
Journal:  Circulation       Date:  2007-04-16       Impact factor: 29.690

8.  Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.

Authors:  Jung-Sun Kim; Ik-Kyung Jang; Chunyu Fan; Tae Hoon Kim; Jin-Sun Kim; Sang Min Park; Eui-Young Choi; Sang Hak Lee; Young-Guk Ko; Donghoon Choi; Myeong-Ki Hong; Yangsoo Jang
Journal:  JACC Cardiovasc Interv       Date:  2009-12       Impact factor: 11.195

9.  Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation.

Authors:  Jin-Sun Kim; Jung-Sun Kim; Tae Hoon Kim; Chunyu Fan; Jung Myung Lee; Woong Kim; Young-Guk Ko; Donghoon Choi; Myeong-Ki Hong; Yangsoo Jang
Journal:  Circ J       Date:  2009-12-17       Impact factor: 2.993

10.  Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid model.

Authors:  F Prati; M Zimarino; E Stabile; G Pizzicannella; T Fouad; R Rabozzi; A Filippini; J Pizzicannella; M Cera; R De Caterina
Journal:  Heart       Date:  2007-07-16       Impact factor: 5.994

View more
  2 in total

1.  Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography.

Authors:  Tomohisa Tada; Adnan Kastrati; Robert A Byrne; Tibor Schuster; Rezarta Cuni; Lamin A King; Salvatore Cassese; Michael Joner; Jürgen Pache; Steffen Massberg; Albert Schömig; Julinda Mehilli
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-23       Impact factor: 2.357

2.  Evaluation of IVOCT imaging of coronary artery metallic stents with neointimal coverage.

Authors:  Sahar Elahi; Derek Ho; Marc D Feldman; Jouke Dijkstra; Thomas E Milner
Journal:  Int J Cardiovasc Imaging       Date:  2014-11-14       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.