Literature DB >> 22414984

Protective embolization of the gastroduodenal artery with a one-HydroCoil technique in radioembolization procedures.

R López-Benítez1, P Hallscheidt, C Kratochwil, C Ernst, L Kara, O Rusch, P Vock, J Kettenbach.   

Abstract

PURPOSE: Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection.
METHODS: Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7-21 days) occlusion rates of GDA. Secondary end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects.
RESULTS: In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5-6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30-3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported.
CONCLUSION: We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.

Entities:  

Mesh:

Year:  2012        PMID: 22414984     DOI: 10.1007/s00270-012-0361-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  4 in total

Review 1.  Hydrogel-Coated Coils: Product Description and Clinical Applications.

Authors:  Hector Ferral
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Embolization of liver tumors: Past, present and future.

Authors:  Ashwin Rammohan; Jeswanth Sathyanesan; Sukumar Ramaswami; Anand Lakshmanan; Perumal Senthil-Kumar; Ulagendra Perumal Srinivasan; Ravi Ramasamy; Palaniappan Ravichandran
Journal:  World J Radiol       Date:  2012-09-28

3.  Temperature-induced configuration changes in hydrogel-coated coils and their relevance in embolization procedures.

Authors:  Ruben Lopez Benitez; Tomas Reyes Del Castillo; Levent Kara; Joachim Kettenbach; Justus Roos
Journal:  CVIR Endovasc       Date:  2020-12-10

Review 4.  Endoluminal occlusion devices: technology update.

Authors:  Tobias Zander; Samantha Medina; Guillermo Montes; Lourdes Nuñez-Atahualpa; Michel Valdes; Manuel Maynar
Journal:  Med Devices (Auckl)       Date:  2014-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.