Literature DB >> 22414138

Preliminary study of enteroscopy-guided, self-expandable metal stent placement for malignant small bowel obstruction.

Hyuk Lee1, Jun Chul Park, Sung Kwan Shin, Sang Kil Lee, Yong Chan Lee.   

Abstract

BACKGROUND AND AIMS: Technical limitations of conventional endoscopes and delivery systems frequently hamper palliative endoscopic placement of self-expandable metal stents for malignant small bowel obstruction. This study examined feasibility of the double balloon enteroscope-guided withdrawal-reinsertion method as a rescue procedure in patients with failed palliative stent placement for malignant small bowel obstruction.
METHODS: We enrolled 19 consecutive patients with small bowel obstruction due to metastatic gastric (n = 15) or colorectal cancer (n = 2), or primary small bowel carcinoma (n = 2), in whom previous attempts to place self-expandable metal stents using conventional endoscopy had failed. Ten patients had undergone previous gastric surgery. After passing a guide-wire using an enteroscope with or without the double-balloon method, the enteroscope was withdrawn. A conventional endoscope was re-inserted along the guide-wire, and through-the-scope self-expandable metal stent placement was performed.
RESULTS: Obstruction sites were efferent jejunal loop, proximal jejunum, and third duodenal portion. Technical success was achieved with 94.7% (18/19) of stents, and clinical success occurred with 84.2% (16/19) of patients. The gastric outlet obstruction score (pre-procedure: 0.68 ± 0.58) increased by one week (2.05 ± 0.52, P < 0.001). Stent migration and restenosis occurred in two (10.5%) and four (21.1%) of 19 stents, respectively. Median stent patency duration was 67 days and median survival was 93 days; these did not differ significantly by palliative chemotherapy (P = 0.76 and 0.67, respectively).
CONCLUSIONS: The double-balloon enteroscopy-guided method followed by conventional endoscopic self-expandable metal stent delivery was effective for rescue palliation of malignant small bowel obstruction.
© 2012 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22414138     DOI: 10.1111/j.1440-1746.2012.07113.x

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  11 in total

1.  Percutaneous needle decompression in treatment of malignant small bowel obstruction.

Authors:  Ting-Hui Jiang; Xian-Jun Sun; Yue Chen; Hui-Qin Cheng; Shi-Ming Fang; Hao-Sheng Jiang; Yan Cao; Bing-Yan Liu; Shao-Qiu Wu; Ai-Wu Mao
Journal:  World J Gastroenterol       Date:  2015-02-28       Impact factor: 5.742

2.  Effectiveness of endoscopic self-expandable metal stent placement for afferent loop obstruction caused by pancreatic cancer recurrence after pancreaticoduodenectomy.

Authors:  Arata Sakai; Hideyuki Shiomi; Yoshihiro Okabe; Yousuke Yagi; Takashi Kobayashi; Yuuki Shiomi; Mamoru Takenaka; Namiko Hoshi; Yoshifumi Arisaka; Hiromu Kutsumi; Takeshi Azuma
Journal:  Clin J Gastroenterol       Date:  2015-02-24

3.  A multicenter experience of through-the-scope balloon-assisted enteroscopy in surgically altered gastrointestinal anatomy.

Authors:  Jennifer X Cai; David L Diehl; Ralf Kiesslich; Andrew C Storm; Mohamad H El Zein; Alan H Tieu; Arthur Hoffman; Vikesh K Singh; Mouen A Khashab; Patrick I Okolo; Vivek Kumbhari
Journal:  Surg Endosc       Date:  2016-12-30       Impact factor: 4.584

4.  SEMS vs cSEMS in duodenal and small bowel obstruction: high risk of migration in the covered stent group.

Authors:  Oliver Waidmann; Jörg Trojan; Mireen Friedrich-Rust; Christoph Sarrazin; Wolf Otto Bechstein; Frank Ulrich; Stefan Zeuzem; Jörg Gerhard Albert
Journal:  World J Gastroenterol       Date:  2013-10-07       Impact factor: 5.742

5.  Long-term release of a malignant ileal obstruction by placement of a colorectal self-expandable metal stent.

Authors:  Sho Suzuki; Chika Kusano; Natsuko Yoshizawa; Masakatsu Nakamura; Toshiaki Hirasawa; Takuji Gotoda; Fuminori Moriyasu
Journal:  Clin J Gastroenterol       Date:  2013-03-26

6.  Role of double-balloon enteroscopy in malignant small bowel tumors.

Authors:  Enrique Pérez-Cuadrado Robles; Pilar Esteban Delgado; Paloma Bebia Conesa; Blanca Martínez Andrés; Milivoj Franulic Guggiana; Eduardo Alcaraz Mateos; Mariana Fernández Caballero; José Luis Rodrigo Agudo; Silvia Chacón Martínez; Rafael Latorre; Federico Soria; Juan Manuel Herrerías Gutiérrez; Enrique Pérez-Cuadrado Martínez
Journal:  World J Gastrointest Endosc       Date:  2015-06-10

7.  Combined use of single-balloon enteroscope and colonoscope for self-expandable metal stent placement in patients with malignant small intestinal obstruction: a single-center comparative clinical observation.

Authors:  Ya-Fei Zhang; Shou-Bin Ning; Bai-Rong Li; Jing Zhang; Jing Li; Jie Tang; Ming Zhu; Xiao-Wei Jin; Qiu Zhao; Gao-Ping Mao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

8.  Safety and efficacy of self-expandable metallic stents in malignant small bowel obstructions.

Authors:  Akiyoshi Tsuboi; Toshio Kuwai; Tomoyuki Nishimura; Sumio Iio; Takeshi Mori; Hiroki Imagawa; Toshiki Yamaguchi; Atsushi Yamaguchi; Hirotaka Kouno; Hiroshi Kohno
Journal:  World J Gastroenterol       Date:  2016-10-28       Impact factor: 5.742

9.  Recurrence of Obstructive Symptoms and Quality of Life after Insertion of Non-Cover Metal Stent Inside the Biliary Duct in Patients with Pancreatic Cancer.

Authors:  Hassan Salmanroghani; Samira Akbarian; Roham Salman Roghani
Journal:  Maedica (Bucur)       Date:  2020-03

10.  Small Bowel Stent-in-Stent Placement for Malignant Small Bowel Obstruction Using a Balloon-Assisted Overtube Technique.

Authors:  Daniel Popa; Jayapal Ramesh; Shajan Peter; C Mel Wilcox; Klaus Mönkemüller
Journal:  Clin Endosc       Date:  2014-01-24
View more