Literature DB >> 22407394

Changes in anterior segment parameters after insertion of Ex-PRESS miniature glaucoma implant.

Naʼama Hammel1, Moshe Lusky, Igor Kaiserman, Anat Robinson, Irit Bahar.   

Abstract

PURPOSE: The aim of this study was to evaluate the effect of Ex-PRESS Miniature Glaucoma Implant surgery on corneal curvature and anterior segment parameters obtained with the Pentacam rotating Scheimpflug camera (Oculus Inc.). PATIENTS/
METHODS: In this prospective study, a total of 19 eyes of 19 consecutive patients (11 men, 8 women) were evaluated preoperatively, on the first postoperative day, and at 1 week, 1 month, and 3 months postoperatively with the Pentacam. We compared measurements of anterior and posterior corneal curvature, anterior and posterior corneal astigmatism, anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle before and after surgery. All study eyes were pseudophakic.
RESULTS: Intraocular pressure decreased significantly from 31.9±10.1 mmHg preoperatively to 6.1±5.7 mmHg on the first postoperative day (P<0.0001) and 15.7±3.6 mmHg at 3 months after surgery (P=0.0011). On the first postoperative day, the anterior corneal astigmatism increased from 2.6±3.3 to 4.7±3.1 D (P=0.19), the posterior corneal astigmatism increased from 0.4±0.2 to 0.9±0.5 D (P=0.008), the ACD decreased from 4.3±0.7 to 3.5±1 mm (P=0.015), and the ACV decreased from 193±35 to 160±49 mm (P=0.006). All of these changes in anterior segment parameters were not statistically significant at 3 months after surgery.
CONCLUSIONS: Ex-PRESS Miniature Glaucoma Implant surgery significantly decreased intraocular pressure and had a transient effect on anterior segment parameters. Corneal curvatures, ACD, ACV, and anterior chamber angle were not affected at 3 months of follow-up.

Entities:  

Mesh:

Year:  2013        PMID: 22407394     DOI: 10.1097/IJG.0b013e31824d4fa1

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  7 in total

1.  Effects of primary selective laser trabeculoplasty on anterior segment parameters.

Authors:  Suzan Guven Yilmaz; Melis Palamar; Emil Yusifov; Halil Ates; Sait Egrilmez; Ayse Yagci
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

3.  Indications and postoperative treatment for Ex-PRESS(®) insertion in Japanese patients with glaucoma: comparison with standard trabeculectomy.

Authors:  Noriko Kato; Genichiro Takahashi; Koichi Kumegawa; Yoshiaki Kabata; Hiroshi Tsuneoka
Journal:  Clin Ophthalmol       Date:  2015-08-18

Review 4.  Glaucoma surgery and induced astigmatism: a systematic review.

Authors:  Helen H L Chan; Yu Xiang G Kong
Journal:  Eye Vis (Lond)       Date:  2017-11-17

5.  Refractive outcomes after trabecular microbypass stent with cataract extraction in open-angle glaucoma.

Authors:  Rachel A Scott; Tanner J Ferguson; John D Stephens; John P Berdahl
Journal:  Clin Ophthalmol       Date:  2019-07-25

6.  Phacotrabeculectomy versus Phaco with Implantation of the Ex-PRESS Device: Surgical and Refractive Outcomes-A Randomized Controlled Trial.

Authors:  Joanna Konopińska; Anna Byszewska; Emil Saeed; Zofia Mariak; Marek Rękas
Journal:  J Clin Med       Date:  2021-01-22       Impact factor: 4.241

7.  Meta-analysis of randomized controlled trials comparing EX-PRESS implantation with trabeculectomy for open-angle glaucoma.

Authors:  Wei Wang; Xiulan Zhang
Journal:  PLoS One       Date:  2014-06-27       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.