A prospective multicenter registry of laser therapy for degenerated saphenous vein graft stenosis: the COronary graft Results following Atherectomy with Laser (CORAL) trial.

Gregory R Giugliano1, M Wayne Falcone, David Mego, Doug Ebersole, Steve Jenkins, Tony Das, Esmund Barker, Joseph M Ruggio, Brijeshwar Maini, Steven R Bailey.   

Abstract

PURPOSE: The primary aim of this study was to prospectively evaluate the safety and efficacy of Excimer laser atherectomy as a primary treatment strategy in consecutively eligible patients presenting for percutaneous coronary intervention (PCI) of degenerated saphenous vein graft (SVG) lesions using a multicenter registry. Prior single-center experience suggested that laser atherectomy may decrease acute procedural complications during treatment of degenerated SVGs, including lesions not amenable to distal protection devices (DPDs). METHODS AND MATERIALS: The COronary graft Results following Atherectomy with Laser investigators enrolled 98 patients at 18 centers between June 23, 2003, and October 4, 2004, with greater than 50% stenosis of an SVG who presented for PCI due to angina pectoris or objective evidence of myocardial ischemia in a concordant myocardial distribution. Laser atherectomy was planned. Patients were excluded if the operator planned to utilize a DPD. Inclusion and exclusion criteria were aligned to those in the Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) trial.
RESULTS: The primary end point [30-day major adverse cardiac events (MACE)] occurred in 18/98 (18.4%) patients driven primarily by non-q-wave myocardial infarction. Major procedural complications included no reflow (n=5) and major dissection (n=1). No perforations occurred. Univariate predictors of 30-day MACE included lesion length, vessel angulation, plaque burden, SVG degeneracy score, number of laser pulses used, and larger-sized laser catheters.
CONCLUSIONS: This study demonstrated that Excimer laser atherectomy of diseased SVGs is feasible with results comparable to the 30-day MACE in the control population from the SAFER trial. Whether the addition of laser to embolic protection devices is of any clinical utility remains to be tested in future studies.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22406059     DOI: 10.1016/j.carrev.2012.01.004

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  5 in total

1.  Recent publications by ochsner authors.

Authors: 
Journal:  Ochsner J       Date:  2012

2.  Coronary Intervention with the Excimer Laser: Review of the Technology and Outcome Data.

Authors:  John Rawlins; Jehangir N Din; Suneel Talwar; Peter O'Kane
Journal:  Interv Cardiol       Date:  2016-05

3.  Saphenous vein graft interventions.

Authors:  Emmanouil S Brilakis; Michael Lee; Julinda Mehilli; Konstantinos Marmagkiolis; Josep Rodes-Cabau; Rajesh Sachdeva; Anna Kotsia; George Christopoulos; Bavana V Rangan; Atif Mohammed; Subhash Banerjee
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-05

Review 4.  Atherectomy devices: technology update.

Authors:  Nuri I Akkus; Abdulrahman Abdulbaki; Enrique Jimenez; Neeraj Tandon
Journal:  Med Devices (Auckl)       Date:  2014-12-17

5.  Percutaneous recanalization of total saphenous vein graft occlusion with excimer laser treatment.

Authors:  Yuan Han; Quan-Min Jing; Qian-Cheng Wang; Yan-Bin Su; Guo-Jun Chen
Journal:  J Geriatr Cardiol       Date:  2020-04       Impact factor: 3.327

  5 in total