Literature DB >> 22405310

Fission track-secondary ion mass spectrometry as a tool for detecting the isotopic signature of individual uranium containing particles.

Fumitaka Esaka1, Chi-Gyu Lee, Masaaki Magara, Takaumi Kimura.   

Abstract

A fission track technique was used as a sample preparation method for subsequent isotope abundance ratio analysis of individual uranium containing particles with secondary ion mass spectrometry (SIMS) to measure the particles with higher enriched uranium efficiently. A polycarbonate film containing particles was irradiated with thermal neutrons and etched with 6M NaOH solution. Each uranium containing particle was then identified by observing fission tracks created and a portion of the film having a uranium containing particle was cut out and put onto a glassy carbon planchet. The polycarbonate film, which gave the increases of background signals on the uranium mass region in SIMS analysis, was removed by plasma ashing with 200 W for 20 min. In the analysis of swipe samples having particles containing natural (NBL CRM 950a) or low enriched uranium (NBL CRM U100) with the fission track-SIMS method, uranium isotope abundance ratios were successfully determined. This method was then applied to the analysis of a real inspection swipe sample taken at a nuclear facility. As a consequence, the range of (235)U/(238)U isotope abundance ratio between 0.0276 and 0.0438 was obtained, which was higher than that measured by SIMS without using a fission track technique (0.0225 and 0.0341). This indicates that the fission track-SIMS method is a powerful tool to identify the particle with higher enriched uranium in environmental samples efficiently. Copyright Â
© 2012 Elsevier B.V. All rights reserved.

Entities:  

Year:  2012        PMID: 22405310     DOI: 10.1016/j.aca.2012.01.045

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Considerations for uranium isotope ratio analysis by atmospheric pressure ionization mass spectrometry.

Authors:  Thomas P Forbes; Christopher Szakal
Journal:  Analyst       Date:  2018-12-17       Impact factor: 4.616

2.  Uranyl-water-containing complexes: solid-state UV-MALDI mass spectrometric and IR spectroscopic approach for selective quantitation.

Authors:  Bojidarka Ivanova; Michael Spiteller
Journal:  Environ Sci Pollut Res Int       Date:  2013-08-13       Impact factor: 4.223

3.  A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L.

Authors:  N Alex Zirakparvar; Cole R Hexel; Julie B Smith; Andrew J Miskowiec; Tyler L Spano; Roger Kapsimalis
Journal:  Sci Rep       Date:  2020-07-23       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.