Literature DB >> 22403129

Doppler-ultrasound measurements in renal allografts depend on the patient's body position.

Dominik Steubl1, Evangelos Papachristou, Petra Wolf, Marcel Roos, Jens Lutz, Uwe Heemann, Konrad F Stock.   

Abstract

BACKGROUND: Due to anatomical reasons a position-dependent renal allograft artery stenosis is being discussed (e.g. only in patient's upright position). The tortuous course of the allograft artery complicates the direct, angle-dependent measurement of maximum systolic flow velocities (vmax). So indirect signs such as intraparenchymal vmax and resistance index might be helpful, but it is unknown how these values change physiologically when patient's body position changes. PATIENTS AND METHODS: We examined renal allografts of 60 patients (38 male, 22 female) with stable graft function using B-Mode-, colour-coded duplex-sonography and pulsed-wave-Doppler. We measured vmax and RI-values of three interlobar arteries in the cortex and allograft artery in the hilus in patients standing upright and in horizontal position. Corresponding values were analyzed for significant differences.
RESULTS: Intraparenchymal RI-values and vmax were significantly reduced in patients upright compared to the horizontal position (16 %, MW=0.59 vs. MW=0.70, p < 0.001 resp. 6 %, MW=30.18 cm/s vs. MW=32.17 cm/s, p = 0.045). Similar results could be detected in the renal hilus.
CONCLUSIONS: Patients with stable graft-function show significant, position-dependent differences of the intraparenchymal and hilar RI-values and maximal systolic flow velocities. These changes of Doppler parameters has to be kept in mind for the correct diagnosis of a position dependent allograft artery stenosis.

Entities:  

Mesh:

Year:  2012        PMID: 22403129     DOI: 10.1024/0301-1526/a000173

Source DB:  PubMed          Journal:  Vasa        ISSN: 0301-1526            Impact factor:   1.961


  2 in total

Review 1.  Vascular applications of ferumoxytol-enhanced magnetic resonance imaging of the abdomen and pelvis.

Authors:  Andrew W Bowman; Cory R Gooch; Lauren F Alexander; Madhura A Desai; Candice W Bolan
Journal:  Abdom Radiol (NY)       Date:  2020-10-22

2.  MR Angiography of Renal Transplant Vasculature with Ferumoxytol:: Comparison of High-Resolution Steady-State and First-Pass Acquisitions.

Authors:  Michael T Corwin; Ghaneh Fananapazir; Abhijit J Chaudhari
Journal:  Acad Radiol       Date:  2015-12-18       Impact factor: 3.173

  2 in total