Abstract

The disadvantages of titanium implants are their low wear resistance and the release of titanium elements into surrounding tissue. These can be eliminated by modifying the surface by surface engineering methods, among them nitriding under glow discharge conditions which allow to produce diffusive surface layers. Their combining with an oxide layer might be valuable for biological events occurring at the bone implant interface. The aim of this study was to enhance the titanium biomaterial performance via combining nitriding and oxidizing treatments in one process under glow discharge conditions. The oxynitrided surface layers were produced at 680 degrees C. The obtained layer was TiO + TiN + Ti2N + alphaTi(N) type and about 4-microm thick and was of diffusive character. This layer significantly increased wear resistance and slightly corrosion resistance compared to that of the reference titanium alloy. The produced titanium oxide was about 400-nm thick and built from fine crystallites. This oxide exhibits bioactivity in SBF (simulated body fluid). Osteoblasts of Saos-2 line incubated on this surface exhibited good adhesion and proliferation and ALP release comparable with cells cultured on the reference titanium alloy and TiN + Ti2N + alphaTi(N) surface layers. A quantitative analysis of blood platelets adhering to this layer revealed their highest amount in comparison to that on both the nitrided surface layer and titanium alloy. The presented study provided a simple and reproducible method of combining oxidizing and nitriding under glow discharge in one process. Experimental data in vitro suggests that titanium alloy oxynitriding under low temperatures at glow discharge conditions improves titanium alloy properties and biocompatibility and tissue healing. Therefore, the layer of TiO + TiN +Ti2N + alphaTi(N) type could be valuable for long-term bone implants.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22400281     DOI: 10.1166/jnn.2011.3474

Source DB:  PubMed          Journal:  J Nanosci Nanotechnol        ISSN: 1533-4880


  5 in total

1.  Bone response to surface-modified titanium implants: studies on the early tissue response to implants with different surface characteristics.

Authors:  C Larsson Wexell; P Thomsen; B-O Aronsson; P Tengvall; M Rodahl; J Lausmaa; B Kasemo; L E Ericson
Journal:  Int J Biomater       Date:  2013-09-23

2.  Electrochemical, Tribological and Biocompatible Performance of Electron Beam Modified and Coated Ti6Al4V Alloy.

Authors:  Maria Nikolova; Maria Ormanova; Veselina Nikolova; Margarita D Apostolova
Journal:  Int J Mol Sci       Date:  2021-06-14       Impact factor: 5.923

Review 3.  The influence of reduced graphene oxide on stem cells: a perspective in peripheral nerve regeneration.

Authors:  Xiangyun Yao; Zhiwen Yan; Xu Wang; Huiquan Jiang; Yun Qian; Cunyi Fan
Journal:  Regen Biomater       Date:  2021-06-25

Review 4.  Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature.

Authors:  Ruud P van Hove; Inger N Sierevelt; Barend J van Royen; Peter A Nolte
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

5.  Structure and properties of composite surface layers produced on NiTi shape memory alloy by a hybrid method.

Authors:  Justyna Witkowska; Agnieszka Sowińska; Elżbieta Czarnowska; Tomasz Płociński; Bogusław Rajchel; Michał Tarnowski; Tadeusz Wierzchoń
Journal:  J Mater Sci Mater Med       Date:  2018-07-17       Impact factor: 3.896

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.