Literature DB >> 22398924

Acupuncture point localization varies among acupuncturists.

Petra I Bäumler1, Michael Simang, Sybille Kramer, Dominik Irnich.   

Abstract

BACKGROUND: Studies assessing the point-specific effect of acupuncture or the characteristics of acupuncture points (APs) tend to yield inconclusive results. In order to identify a possible confounding factor, we aimed to examine the variability in AP localization by means of a survey.
MATERIAL AND METHODS: Attendees of the 14th ICMART (International Council of Medical Acupuncture and Related Techniques) congress as well as DÄGfA (German Medical Society of Acupuncture) lecturers and students were asked to locate and mark the APs LI 10 and TH 5 on a research assistant's arm. Identified points were transferred into a coordinate system, and the respective bivariate distribution function was calculated. Additionally, participants filled out a questionnaire about their acupuncture education and experience, the acupuncture style and point localization techniques used most frequently, and their estimation of the size of an AP.
RESULTS: The areas of the ellipses, theoretically containing 95% of AP localizations, varied between 44.49 and 5.18 cm(2). The largest distance between 2 identified points was 8.45 cm for LI 10 and 5.3 cm for TH 5. Apart from being trained at the same school, no other factor could be identified that determined the variability in AP localization.
CONCLUSION: Our results indicate that congruity of AP localization among experienced acupuncturists might be low. Although there are some limitations to our results, this possible bias should be taken into account when conducting acupuncture trials and interpreting results of previous acupuncture studies.
Copyright © 2012 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2012        PMID: 22398924     DOI: 10.1159/000335825

Source DB:  PubMed          Journal:  Forsch Komplementmed        ISSN: 1661-4119


  3 in total

1.  Is acupuncture "stimulation" a misnomer? A case for using the term "blockade".

Authors:  Morry Silberstein
Journal:  BMC Complement Altern Med       Date:  2013-03-25       Impact factor: 3.659

Review 2.  Neuroimaging and Neuromonitoring Effects of Electro and Manual Acupuncture on the Central Nervous System: A Literature Review and Analysis.

Authors:  Brigitte Elisabeth Scheffold; Ching-Liang Hsieh; Gerhard Litscher
Journal:  Evid Based Complement Alternat Med       Date:  2015-08-03       Impact factor: 2.629

3.  Minimisation of variations in locating an acupuncture point using a laser-device.

Authors:  Dha-Hyun Choi; Younbyoung Chae
Journal:  Integr Med Res       Date:  2019-11-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.