Literature DB >> 22398415

Accuracy of algorithms for detection of atrial fibrillation from short duration beat interval recordings.

P Langley1, M Dewhurst, L Y Di Marco, P Adams, F Dewhurst, J C Mwita, R Walker, A Murray.   

Abstract

Atrial fibrillation (AF) is characterised by highly variable beat intervals. The aims of the study were to assess the accuracy of AF detection algorithms from short analysis durations and to validate prospectively the accuracy on a large community-based cohort of elderly subjects. Three algorithms for AF detection were evaluated: coefficient of variation (CV), mean successive difference (Δ) and coefficient of sample entropy (COSEn), using two databases of beat interval recordings: 167 recordings of 300 s duration for a range of rhythms acquired in a hospital setting and 2130 recordings of 10s duration acquired in the community. Using the longer recordings receiver operating characteristic (ROC) analysis was used to identify optimal algorithm thresholds and to evaluate analysis durations ranging from 5s to 60s. An ROC area of 93% was obtained at recording duration of 60s but remained above 90% for durations as low as 5s. Prospective analysis on the 2130 recordings gave AF detector sensitivities from 90.5% (CV and Δ) to 95.2% (COSEn), specificities from 89.3% (Δ) to 93.4% (COSEn) and accuracy from 89.3% (Δ) to 93.4% (COSEn), not significantly different to those obtained on the initial database. AF detection algorithms are effective for short analysis durations, offering the prospect of a simple and rapid diagnostic test based on beat intervals alone.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22398415     DOI: 10.1016/j.medengphy.2012.02.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  7 in total

1.  Detection of occult paroxysmal atrial fibrillation.

Authors:  Andrius Petrėnas; Leif Sörnmo; Arūnas Lukoševičius; Vaidotas Marozas
Journal:  Med Biol Eng Comput       Date:  2014-12-14       Impact factor: 2.602

2.  Accuracy of pulse interval timing in ambulatory blood pressure measurement.

Authors:  Sarah A Kane; James R Blake; Frank J McArdle; Philip Langley; Andrew J Sims
Journal:  Sci Rep       Date:  2016-11-23       Impact factor: 4.379

3.  Atrial Fibrillation Beat Identification Using the Combination of Modified Frequency Slice Wavelet Transform and Convolutional Neural Networks.

Authors:  Xiaoyan Xu; Shoushui Wei; Caiyun Ma; Kan Luo; Li Zhang; Chengyu Liu
Journal:  J Healthc Eng       Date:  2018-07-02       Impact factor: 2.682

4.  Feasibility of atrial fibrillation detection from a novel wearable armband device.

Authors:  Syed Khairul Bashar; Md-Billal Hossain; Jesús Lázaro; Eric Y Ding; Yeonsik Noh; Chae Ho Cho; David D McManus; Timothy P Fitzgibbons; Ki H Chon
Journal:  Cardiovasc Digit Health J       Date:  2021-05-21

5.  Detection and categorization of severe cardiac disorders based solely on heart period measurements.

Authors:  Shigeru Shinomoto; Yasuhiro Tsubo; Yoshinori Marunaka
Journal:  Sci Rep       Date:  2022-10-11       Impact factor: 4.996

6.  Novel Density Poincaré Plot Based Machine Learning Method to Detect Atrial Fibrillation From Premature Atrial/Ventricular Contractions.

Authors:  Syed Khairul Bashar; Dong Han; Fearass Zieneddin; Eric Ding; Timothy P Fitzgibbons; Allan J Walkey; David D McManus; Bahram Javidi; Ki H Chon
Journal:  IEEE Trans Biomed Eng       Date:  2021-01-20       Impact factor: 4.538

7.  A Detector for Premature Atrial and Ventricular Complexes.

Authors:  Guadalupe García-Isla; Luca Mainardi; Valentina D A Corino
Journal:  Front Physiol       Date:  2021-06-16       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.