Literature DB >> 22396024

High sensitivity steroid analysis using liquid chromatography/solvent-assisted inlet ionization mass spectrometry.

Nicholas D Chubatyi1, Vincent S Pagnotti, Catherine M Bentzley, Charles N McEwen.   

Abstract

RATIONALE: Steroids can be injected to behave as therapeutic agents to promote muscle growth and strength. Areas of concern include synthetic steroids in consumer meat and milk products and the presence of anabolic steroids in athletes. Here we demonstrate a new ionization method for high sensitivity steroid analysis using liquid chromatography/mass spectrometry (LC/MS).
METHODS: Solvent-assisted inlet ionization (SAII) mass spectrometry was coupled directly to an infusion pump or to a liquid chromatograph to determine the limits of detection and quantitation for selected steroids. LC/MS/MS data was acquired on a quadrupole time-of-flight (QTOF) mass spectrometer and high resolution-accurate mass LC/MS data was obtained on an Orbitrap mass spectrometer.
RESULTS: The SAII limit of detection for infusion into the Orbitrap using high mass resolution and accurate mass was shown, for the steroids studied, to be low ppqt and the limit of quantitation using LC/MS was low ppt. Low ppb levels were detected with high signal-to-noise from spiked urine using a simple Ziptip procedure without sample concentration.
CONCLUSIONS: LC/SAII-MS is more sensitive than electrospray ionization (ESI) at similar mobile phase flow rates for the analysis of steroids. Previous studies have shown LC/SAII-MS to have high sensitivity for analysis of peptides. The combined results suggests this easy to implement ionization method may advantageously replace ESI for a wide range of analyses.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22396024     DOI: 10.1002/rcm.6179

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Carbonation and other super saturated gases as solution modifiers for improved sensitivity in solvent assisted ionization inlet (SAII) and ESI.

Authors:  Vincent S Pagnotti; Shubhashis Chakrabarty; Charles N McEwen
Journal:  J Am Soc Mass Spectrom       Date:  2013-01-08       Impact factor: 3.109

2.  Improving the Sensitivity of Matrix-Assisted Ionization (MAI) Mass Spectrometry Using Ammonium Salts.

Authors:  Nicholas D Chubatyi; Charles N McEwen
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-30       Impact factor: 3.109

3.  "Magic" Ionization Mass Spectrometry.

Authors:  Sarah Trimpin
Journal:  J Am Soc Mass Spectrom       Date:  2016-01       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.