Literature DB >> 22392689

Performance evaluation of a tailor-made passive sampler for monitoring of tropospheric ozone.

Ozlem Ozden1, Tuncay Döğeroğlu.   

Abstract

INTRODUCTION: This study presents the performance evaluation of a tailor-made passive sampler developed for the monitoring of tropospheric ozone.
METHODS: The performance of the passive sampler was tested in the field conditions in terms of accuracy, precision, blank values, detection limit, effects of some parameters such as sampling site characteristics and sampling period on the field blanks, self-consistency, experimental and theoretical uptake rates, shelf life and comparison with commercial passive samplers.
RESULTS: There was an agreement (R (2) = 0.84) between the responses of passive sampler and the continuous automatic analyser. The accuracy of the sampler, expressed as percent relative error, was obtained lower than 15%. Method precision in terms of coefficient of variance for three simultaneously applied passive samplers was 12%. Sampler detection limit was 2.42 μg m(-3) for an exposure period of 1 week, and the sampler can be stored safely for a period of up to 8 weeks before exposure. Satisfactory self-consistency results showed that extended periods gave the same integrated response as a series of short-term samplers run side by side. The uptake rate of ozone was found to be 10.21 mL min(-1) in a very good agreement with the theoretical uptake rate (10.32 mL min(-1)). The results of the comparison study conducted against a commercially available diffusion tube (Gradko diffusion tube) showed a good linear relationship (R (2) = 0.93) between two passive samplers.
CONCLUSIONS: The sampler seems suitable to be used in large-scale measurements of ozone where no data are available or the number of existing automated monitors is not sufficient.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22392689     DOI: 10.1007/s11356-012-0825-0

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  22 in total

1.  Use of passive ambient ozone (O3) samplers in vegetation effects assessment.

Authors:  S Krupa; M Nosal; D L Peterson
Journal:  Environ Pollut       Date:  2001       Impact factor: 8.071

2.  The use of passive sampling to monitor forest exposure to O3, NO2 and SO2: a review and some case studies.

Authors:  Roger M Cox
Journal:  Environ Pollut       Date:  2003       Impact factor: 8.071

3.  Ozone monitoring in a Mediterranean forest using diffusive and continuous sampling.

Authors:  Franco De Santis; Donatella Zona; Raffaella Bellagotti; Francesca Vichi; Ivo Allegrini
Journal:  Anal Bioanal Chem       Date:  2004-11       Impact factor: 4.142

4.  Passive sampling and/or extraction techniques in environmental analysis: a review.

Authors:  Jacek Namieśnik; Bozena Zabiegała; Agata Kot-Wasik; Monika Partyka; Andrzej Wasik
Journal:  Anal Bioanal Chem       Date:  2004-10-23       Impact factor: 4.142

5.  Radial diffusive sampler for the determination of 8-h ambient ozone concentrations.

Authors:  H Plaisance; M Gerboles; A Piechocki; F Detimmerman; E de Saeger
Journal:  Environ Pollut       Date:  2007-01-26       Impact factor: 8.071

6.  Evaluation of air quality by passive and active sampling in an urban city in Turkey: current status and spatial analysis of air pollution exposure.

Authors:  Eftade O Gaga; Tuncay Döğeroğlu; Ozlem Ozden; Akif Ari; Ozan Devrim Yay; Hicran Altuğ; Nesimi Akyol; Sermin Ornektekin; Wim Van Doorn
Journal:  Environ Sci Pollut Res Int       Date:  2012-04-26       Impact factor: 4.223

7.  Passive sampling for ozone.

Authors:  C Monn; M Hangartner
Journal:  J Air Waste Manage Assoc       Date:  1990-03

8.  Specific spectrophotometric determination of ozone in the atmosphere using 1,2-di(4-pyridyl)ethylene.

Authors:  T R Hauser; D W Bradley
Journal:  Anal Chem       Date:  1966-10       Impact factor: 6.986

9.  Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization.

Authors:  I-Su Lee; Shih-Wei Tsai
Journal:  Anal Chim Acta       Date:  2008-01-19       Impact factor: 6.558

10.  Respiratory health symptoms among students exposed to different levels of air pollution in a Turkish city.

Authors:  Hülya Gül; Eftade O Gaga; Tuncay Döğeroğlu; Özlem Özden; Özkan Ayvaz; Sevda Özel; Günay Güngör
Journal:  Int J Environ Res Public Health       Date:  2011-04-14       Impact factor: 3.390

View more
  1 in total

1.  Evaluation of air quality by passive and active sampling in an urban city in Turkey: current status and spatial analysis of air pollution exposure.

Authors:  Eftade O Gaga; Tuncay Döğeroğlu; Ozlem Ozden; Akif Ari; Ozan Devrim Yay; Hicran Altuğ; Nesimi Akyol; Sermin Ornektekin; Wim Van Doorn
Journal:  Environ Sci Pollut Res Int       Date:  2012-04-26       Impact factor: 4.223

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.