Literature DB >> 22392373

LC-MS/MS fast analysis of androgenic steroids in urine.

Barbara Wozniak1, Iwona Matraszek-Zuchowska, Jan Zmudzki.   

Abstract

The liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated to detect androgenic steroids: trenbolone, nortestosterone, boldenone, methylboldenone, testosterone, methyltestosterone, 17β-1-testosterone and their metabolites in bovine urine. Sample preparation before LC-MS/MS analysis involved an enzymatic hydrolysis with glucuronidase AS-HP, isolation of free hormones from urine on C(18) SPE column and purification of the extract using liquid-liquid extraction with n-pentane and SPE NH(2) column. For the chromatographic separation of steroids, the Poroshell 120-EC C18 column (150 × 2.1 mm, 2.7 μm) was used. Mass spectrometric measurement was achieved using the API 4000 triple quadrupole (QqQ) instrument with a TurboIon-Spray source operating in positive electrospray ionization mode. The procedure was validated according to the Decision 2002/657/EC. Recovery ranged from 76.5% to 118.9% for all examined compounds. The repeatability was below 20% and reproducibility did not exceed the 25%. The linearity was good for all analytes in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limit (CCα) ranged from 0.10 to 0.17 μg L(-1) for all analytes, whereas the detection capability (CCβ) ranged from 0.17 to 0.29 μg L(-1). The application of an innovative Poroshell column allowed for very good chromatographic separation of steroids with a much shorter time of analysis.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22392373     DOI: 10.1007/s00216-012-5859-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Lithium ion adduction enables UPLC-MS/MS-based analysis of multi-class 3-hydroxyl group-containing keto-steroids.

Authors:  Qiuyi Wang; Kimiko Shimizu; Kanako Maehata; Yue Pan; Koki Sakurai; Takatoshi Hikida; Yoshitaka Fukada; Toshifumi Takao
Journal:  J Lipid Res       Date:  2020-02-26       Impact factor: 5.922

2.  Urinary Concentrations of Steroids in Bulls under Anabolic Treatment by Revalor-XS® Implant.

Authors:  Giancarlo Biancotto; Roberto Stella; Federica Barrucci; Francesca Lega; Roberto Angeletti
Journal:  J Anal Methods Chem       Date:  2016-10-20       Impact factor: 2.193

3.  Development of LC-MS/MS Confirmatory Method for the Determination of Testosterone in Bovine Serum.

Authors:  Barbara Woźniak; Iwona Matraszek-Żuchowska; Sebastian Witek; Andrzej Posyniak
Journal:  J Vet Res       Date:  2017-04-04       Impact factor: 1.744

4.  Serum Steroid Ratio Profiles in Prostate Cancer: A New Diagnostic Tool Toward a Personalized Medicine Approach.

Authors:  Adriana Albini; Antonino Bruno; Barbara Bassani; Gioacchino D'Ambrosio; Giuseppe Pelosi; Paolo Consonni; Laura Castellani; Matteo Conti; Simone Cristoni; Douglas M Noonan
Journal:  Front Endocrinol (Lausanne)       Date:  2018-04-05       Impact factor: 5.555

Review 5.  Analytical Methods for the Determination of Neuroactive Steroids.

Authors:  Michal Kaleta; Jana Oklestkova; Ondřej Novák; Miroslav Strnad
Journal:  Biomolecules       Date:  2021-04-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.