| Literature DB >> 22392244 |
Daila Urnau1, Tania Maria Tochetto.
Abstract
UNLABELLED: The association between tinnitus and hyperacusis is common according to the literature. AIM: To verify the occurrence and the suppression effect of transient otoacoustic emissions (TEOAE), the existence of association between tinnitus degrees and hyperacusis degrees, and between the suppressive effect of TEOAE and laterality, tinnitus and hyperacusis degrees in normal hearing adults with complaints of tinnitus and hyperacusis.Entities:
Mesh:
Year: 2012 PMID: 22392244 PMCID: PMC9443871 DOI: 10.1590/s1808-86942012000100014
Source DB: PubMed Journal: Braz J Otorhinolaryngol ISSN: 1808-8686
Figure 1Occurrence of TOAE per frequency range in normal-hearing subjects with complaints of hyperacusis and tinnitus per frequency range. RE – right ear. LE – left ear
Occurrence of TOAE suppression per frequency range in right and left ears of normal-hearing subjects with tinnitus and hyperacusis.
| Frequency | Right ear | Left ear |
|---|---|---|
| 1000 Hz | ||
| Suppression | 11(61.1%) | 13(81.2%) |
| No suppression | 7 (38.9%) | 3 (18.8%) |
| 1500 Hz | ||
| Suppression | 13 (72.2%) | 14 (87.5%) |
| No suppression | 5 (27.8%) | 2 (12.5%) |
| 2000 Hz | ||
| Suppression | 8 (50%) | 13 (81.2%) |
| No suppression | 8 (50%) | 3 (18.8%) |
| 3000 Hz | ||
| Suppression | 14 (70%) | 9 (69.2%) |
| No suppression | 6 (30%) | 4 (30.8%) |
| 4000 Hz | ||
| Suppression | 5 (62.5%) | 9(90%) |
| No suppression | 3 (37.5%) | 1 (10%) |
Figure 2Mean TOAE suppression amplitude per frequency range in the right and left ears. RE – right ear. LE – left ear.
Handedness and occurrence of TOAE suppression in the right ear.
| Handedness | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Right-handed | 16 (84.2%) | 3 (15.8%) |
| Left-handed | 1 (33.3%) | 2 (66.7%) |
Fisher's exact test (p= 0.12).
Handedness and occurrence of TOAE suppression in the left ear.
| Handedness | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Right-handed | 16 (94.1%) | 1 (5.9%) |
| Left-handed | 1 (100%) | 0 (0%) |
Fisher's exact test (p= 1.0).
Degrees of tinnitus and occurrence of TOAE suppression in the right ear.
| Degrees of Tinnitus (THI) | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Slight and Mild | 11 (73.3%) | 4 (26.7%) |
| Moderate, Severe, and Catastrophic | 6 (75%) | 2 (25%) |
Fisher's exact test (p=1.0).
Degrees of tinnitus and occurrence of TOAE suppression in the left ear.
| Degrees of Tinnitus (THI) | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Slight and Mild | 10 (100%) | 0 (0%) |
| Moderate, Severe, and Catastrophic | 7 (87.5%) | 1 (12.5%) |
Fisher's exact test (p=0.44).
Figure 3Degrees of hyperacusis based on the LDL in right and left ears of normal-hearing subjects with complaints of hyperacusis and tinnitus. RE – right ear. LE – left ear.
Degrees of hyperacusis based on the LDL and occurrence of TOAE suppression in the right ear.
| Degrees of Hyperacusis (LDL) | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Negative and Mild | 8 (72.7%) | 3 (27.3%) |
| Moderate and Severe | 11 (91.7%) | 1 (8.3%) |
Fisher's exact test (p=0.32).
Degrees of hyperacusis based on the LDL and occurence of TOAE suppression in the left ear.
| Degrees of hyperacusis (LDL) | TOAE suppression | |
|---|---|---|
| Present | Absent | |
| Negative and Mild | 8 (100%) | 0 (0%) |
| Moderate and Severe | 9 (90%) | 1 (10%) |
Fisher's exact test (p=1.0).