US-fluoroscopy registration for transcatheter aortic valve implantation.

Pencilla Lang1, Petar Seslija, Michael W A Chu, Daniel Bainbridge, Gerard M Guiraudon, Douglas L Jones, Terry M Peters.   

Abstract

Transcatheter aortic valve implantation is a minimally invasive alternative to open-heart surgery for aortic stenosis in which a stent-based bioprosthetic valve is delivered into the heart on a catheter. Limited visualization during this procedure can lead to severe complications. Improved visualization can be provided by live registration of transesophageal echo (TEE) and fluoroscopy images intraoperatively. Since the TEE probe is always visible in the fluoroscopy image, it is possible to track it using fiducial-based single-perspective pose estimation. In this study, inherent probe tracking performance was assessed, and TEE to fluoroscopy registration accuracy and robustness were evaluated. Results demonstrated probe tracking errors of below 0.6 mm and 0.2°, a 2-D RMS registration error of 1.5 mm, and a tracking failure rate of below 1%. In addition to providing live registration and better accuracy and robustness compared to existing TEE probe tracking methods, this system is designed to be suitable for clinical use. It is fully automatic, requires no additional operating room hardware, does not require intraoperative calibration, maintains existing procedure and imaging workflow without modification, and can be implemented in all cardiac centers at extremely low cost.

Entities:  

Mesh:

Year:  2012        PMID: 22389142     DOI: 10.1109/TBME.2012.2189392

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  8 in total

1.  Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system.

Authors:  Charles R Hatt; Michael T Tomkowiak; David A P Dunkerley; Jordan M Slagowski; Tobias Funk; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

2.  A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

Authors:  Martin G Wagner; Charles R Hatt; David A P Dunkerley; Lindsay E Bodart; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

3.  A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidance.

Authors:  Zhe Luo; Junfeng Cai; Lixu Gu
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-01-11       Impact factor: 2.924

4.  Real-time pose estimation of devices from x-ray images: Application to x-ray/echo registration for cardiac interventions.

Authors:  Charles R Hatt; Michael A Speidel; Amish N Raval
Journal:  Med Image Anal       Date:  2016-05-03       Impact factor: 8.545

5.  MRI-3D ultrasound-X-ray image fusion with electromagnetic tracking for transendocardial therapeutic injections: in-vitro validation and in-vivo feasibility.

Authors:  Charles R Hatt; Ameet K Jain; Vijay Parthasarathy; Andrew Lang; Amish N Raval
Journal:  Comput Med Imaging Graph       Date:  2013-04-03       Impact factor: 4.790

6.  Novel System for Real-Time Integration of 3-D Echocardiography and Fluoroscopy for Image-Guided Cardiac Interventions: Preclinical Validation and Clinical Feasibility Evaluation.

Authors:  Aruna V Arujuna; R James Housden; Yingliang Ma; Ronak Rajani; Gang Gao; Niels Nijhof; Pascal Cathier; Roland Bullens; Geert Gijsbers; Victoria Parish; Stamatis Kapetanakis; Jane Hancock; C Aldo Rinaldi; Michael Cooklin; Jaswinder Gill; Martyn Thomas; Mark D O'neill; Reza Razavi; Kawal S Rhode
Journal:  IEEE J Transl Eng Health Med       Date:  2014-01-30       Impact factor: 3.316

7.  Technical and clinical study of x-ray-based surface echo probe tracking using an attached fiducial apparatus.

Authors:  Lindsay E Bodart; Benjamin R Ciske; Jonathan Le; Nicole M Reilly; Roderick C Deaño; Steven M Ewer; Parag Tipnis; Peter S Rahko; Martin G Wagner; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2021-03-25       Impact factor: 4.071

8.  3D-XGuide: open-source X-ray navigation guidance system.

Authors:  Ina Vernikouskaya; Dagmar Bertsche; Wolfgang Rottbauer; Volker Rasche
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-10-15       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.