Literature DB >> 22386146

A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging.

Rachel E Clough1, Matthew Waltham, Daniel Giese, Peter R Taylor, Tobias Schaeffter.   

Abstract

INTRODUCTION: Medical management of type B aortic dissection can result in progressive dilation of the false lumen and poor long-term outcome. Recent studies using models of aortic dissection have suggested flow characteristics, such as stroke volume, velocity, and helicity, are related to aortic expansion. The aim of this study was to assess whether four-dimensional phase-contrast magnetic resonance imaging (4D PC-MRI) can accurately visualize and quantify flow characteristics in patients with aortic dissection and whether these features are related to the rate of aortic expansion.
METHODS: Twelve consecutive patients with medically treated type B thoracic aortic dissection underwent a three-dimensional (3D) MRI anatomy scan using a blood pool contrast agent. Two-dimensional phase contrast MRI data (2D PC-MRI) were acquired in the ascending and descending aorta and 4D PC-MRI data were acquired in the entire thoracic aorta. The 2D PC-MRI measurements were used to assess the quality of the 4D PC-MRI velocity data. Stroke volume, velocity, and the direction of flow were calculated using 4D PC-MRI and related to the rate of aortic expansion measured on contrast-enhanced computed tomography.
RESULTS: Comparison of 2D PC-MRI and 4D PC-MRI measurements showed good correlation (Pearson R(2) = 0.98; 95% confidence interval [CI], 0.9818-0.9953; P < .0001) and no proportional bias (bias = 1.0 mL; standard deviation, 4.6). The median aortic growth rate was 6.1 mm/y (interquartile range [IQR], 1.1-15.1 mm/y), and this correlated well with the growth rate of the false lumen (Spearman ρ = 0.62; 95% CI, 0.06-0.89; P = .0347). False lumen thrombosis (FLT) was seen in 7 of 12 patients and was not associated with reduced aortic expansion rate (FLT present: 11.4 mm/y; IQR, 3.6-21.4) vs FLT absent: 9.9 mm/y; IQR, 3.4-24.2; Mann-Whitney P = .8763). False lumen stroke volume and velocity were associated with more rapid aortic expansion (ρ = 0.80 [95% CI, 0.39-0.94; P = .0029] and ρ = 0.59 [95% CI, 0.09-0.87; P = .0480] respectively). The position of the dominant entry tear was associated with rapid expansion, which tended to be higher with distal vs proximal entry tears (distal, 21.4 mm/y [IQR, 11.4-48.9] vs proximal, 5.5 mm/y [IQR, 3.4-16.6]; Mann-Whitney P = .096). Helical flow was seen in the false lumen in 8 of 12 patients and was related to the rate of aortic expansion (ρ = 0.83, P = .0154).
CONCLUSIONS: 4D PC-MRI can be accurately applied to visualize and quantify flow characteristics in patients with aortic dissection. Stroke volume, velocity, distal dominant entry tears, and helical flow are related to the rate of aortic expansion. This study demonstrates the potential of this new imaging method. A larger prospective study is now required to measure flow characteristics and determine their predictive value for risk stratification of patients with aortic dissection.
Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22386146     DOI: 10.1016/j.jvs.2011.11.005

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  35 in total

Review 1.  Important advances in technology and unique applications related to cardiac magnetic resonance imaging.

Authors:  Mohamad G Ghosn; Dipan J Shah
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

2.  Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease.

Authors:  Pim van Ooij; Julio Garcia; Wouter V Potters; S Chris Malaisrie; Jeremy D Collins; James C Carr; Michael Markl; Alex J Barker
Journal:  J Magn Reson Imaging       Date:  2015-10-19       Impact factor: 4.813

3.  Importance of dynamic aortic evaluation in planning TEVAR.

Authors:  Guido H W van Bogerijen; Joost A van Herwaarden; Michele Conti; Ferdinando Auricchio; Vincenzo Rampoldi; Santi Trimarchi; Frans L Moll
Journal:  Ann Cardiothorac Surg       Date:  2014-05

4.  Total aortic repair: the new paradigm in the treatment of acute type A aortic dissection.

Authors:  George Matalanis; Nisal K Perera; Sean D Galvin
Journal:  Ann Cardiothorac Surg       Date:  2016-05

Review 5.  New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI.

Authors:  Keiichi Itatani; Shohei Miyazaki; Tokoki Furusawa; Satoshi Numata; Sachiko Yamazaki; Kazuki Morimoto; Rina Makino; Hiroko Morichi; Teruyasu Nishino; Hitoshi Yaku
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-09-19

6.  Improved respiratory navigator gating for thoracic 4D flow MRI.

Authors:  Pim van Ooij; Edouard Semaan; Susanne Schnell; Shivraman Giri; Zoran Stankovic; James Carr; Alex J Barker; Michael Markl
Journal:  Magn Reson Imaging       Date:  2015-05-02       Impact factor: 2.546

7.  Accelerated analysis of three-dimensional blood flow of the thoracic aorta in stroke patients.

Authors:  Thomas Wehrum; Miriam Kams; Laure Schroeder; Johann Drexl; Anja Hennemuth; Andreas Harloff
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-15       Impact factor: 2.357

8.  MRI hemodynamic markers of progressive bicuspid aortic valve-related aortic disease.

Authors:  Michael D Hope; Monica Sigovan; S Jarrett Wrenn; David Saloner; Petter Dyverfeldt
Journal:  J Magn Reson Imaging       Date:  2013-10-29       Impact factor: 4.813

9.  Volumetric quantification of absolute local normalized helicity in patients with bicuspid aortic valve and aortic dilatation.

Authors:  Julio Garcia; Alex J Barker; Jeremy D Collins; James C Carr; Michael Markl
Journal:  Magn Reson Med       Date:  2016-08-19       Impact factor: 4.668

10.  Usefulness of new imaging methods for assessment of type B aortic dissection.

Authors:  Rachel E Clough; Vassilios E Zymvragoudakis; Lukla Biasi; Peter R Taylor
Journal:  Ann Cardiothorac Surg       Date:  2014-05
View more