Injectable calcium phosphate cement for augmentation around cancellous bone screws. In vivo biomechanical studies.

S Larsson1, V A Stadelmann, J Arnoldi, M Behrens, B Hess, P Procter, M Murphy, D P Pioletti.   

Abstract

In lower cancellous apparent bone density, it can be difficult to achieve adequate screw fixation and hence stable fracture fixation. Different strategies have been proposed, one of them is through augmentation using calcium phosphate cement in the region at or close to the screw thread itself. To support the hypothesis of an improved screw fixation technique by augmentation of the bone surrounding the implanted screw, in vivo biomechanical and densitometric studies are performed on rabbit specimen where normal and simulated weak bone quality are considered. In particular, the evolution of screw stability till 12 weeks following the implantation is quantified. A statistical significance in the pull out force for augmented versus non-augmented screws was found for the shorter time periods tested of ≤ 5 days whilst the pull out force was found to increase with time for both augmented and non-augmented screws during the 12 week course of the study. The results of the study demonstrate that the use of an injectable calcium phosphate cement which sets in vivo can significantly improve screw pull out strength at and after implantation for normal and simulated weak bone quality.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22386107     DOI: 10.1016/j.jbiomech.2012.02.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Investigating the Effects of Surface-Initiated Polymerization of ε-Caprolactone to Bioactive Glass Particles on the Mechanical Properties of Settable Polymer/Ceramic Composites.

Authors:  Andrew J Harmata; Catherine L Ward; Katarzyna J Zienkiewicz; Joseph C Wenke; Scott A Guelcher
Journal:  J Mater Res       Date:  2014       Impact factor: 3.089

2.  Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting.

Authors:  E B Dolan; M G Haugh; D Tallon; C Casey; L M McNamara
Journal:  J R Soc Interface       Date:  2012-08-22       Impact factor: 4.118

Review 3.  [Implant augmentation in pelvic surgery. Options and technique].

Authors:  N Grüneweller; D Wähnert; M J Raschke; T Fuchs
Journal:  Unfallchirurg       Date:  2015-10       Impact factor: 1.000

4.  Osteosynthesis-screw augmentation by ultrasound-activated biopolymer--an ovine in vivo study assessing biocompatibility and bone-to-implant contact.

Authors:  Hanjo Neumann; Stefan Breer; Nils Reimers; Richard Kasch; Arndt-Peter Schulz; Benjamin Kienast
Journal:  J Orthop Surg Res       Date:  2015-01-28       Impact factor: 2.359

5.  Acetabular Fractures in the Elderly: Midterm Outcomes of Column Stabilisation and Primary Arthroplasty.

Authors:  A Ortega-Briones; S Smith; M Rickman
Journal:  Biomed Res Int       Date:  2017-01-17       Impact factor: 3.411

6.  Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.

Authors:  Thomas Joffre; Per Isaksson; Philip Procter; Cecilia Persson
Journal:  Biomech Model Mechanobiol       Date:  2017-03-06

7.  Biomechanical evaluation of bone screw fixation with a novel bone cement.

Authors:  Tiina Juvonen; Juha-Pekka Nuutinen; Arto P Koistinen; Heikki Kröger; Reijo Lappalainen
Journal:  Biomed Eng Online       Date:  2015-07-30       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.