PURPOSE: To assess the refractive error in the second eye to undergo surgery when the intraocular lens (IOL) power was modified to correct 50% of the error from the first eye when such an error exceeded 0.50 diopter (D).
DESIGN: Prospective, observational case series. PARTICIPANTS: Two hundred fifty patients with bilateral, sequential cataract surgery.
METHODS: Two hundred fifty consecutive patients who underwent the first-eye cataract operation 1 to 3 months earlier were scheduled for cataract surgery in the second eye. When choosing the IOL power for the second eye, the calculations were adjusted to correct 50% of the first-eye refractive error (FERE). The adjusted second-eye refractive error (aSERE) was evaluated 6 to 8 weeks after surgery. It was compared with the FERE, with a potential nonadjusted SERE, and with a potential fully adjusted SERE. MAIN OUTCOME MEASURES: Postoperative refractive error.
RESULTS: The median aSERE was significantly lower in the second eye compared with the median FERE in the 47 cases in which the FERE ranged from -0.50 to -1.00 D (-0.12 vs. -0.66 D), in the 15 cases in which the FERE exceeded -1.00 D (-0.12 vs. -1.25 D), in the 24 cases in which the FERE ranged from 0.50 to 1.00 D (-0.03 vs. 0.65 D), and in the 11 cases in which the FERE exceeded 1.00 D (-0.29 vs. 1.19 D). The difference was statistically significant in all categories (P<0.00001).
CONCLUSIONS: In patients undergoing bilateral sequential cataract surgery and in cases in which the FERE exceeded 0.50 D, the refractive error of the second eye can be improved by modifying the IOL power to correct up to 50% of the error from the first eye. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22385971     DOI: 10.1016/j.ophtha.2012.01.008

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  14 in total

Review 1.  Optimising biometry for best outcomes in cataract surgery.

Authors:  R Sheard
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

2.  The binocular intraocular lens power difference in eyes with different axial lengths.

Authors:  Ming-Hui Deng; Xiao-Gang Wang; Song Chen; Xue-Feng Shi
Journal:  Int J Ophthalmol       Date:  2022-06-18       Impact factor: 1.645

3.  Immediate Sequential vs. Delayed Sequential Bilateral Cataract Surgery: Retrospective Comparison of Postoperative Visual Outcomes.

Authors:  Lisa J Herrinton; Liyan Liu; Stacey Alexeeff; James Carolan; Neal H Shorstein
Journal:  Ophthalmology       Date:  2017-04-21       Impact factor: 12.079

Review 4.  Immediate Sequential Bilateral Cataract Surgery: A Systematic Review and Meta-Analysis.

Authors:  Line Kessel; Jens Andresen; Ditte Erngaard; Per Flesner; Britta Tendal; Jesper Hjortdal
Journal:  J Ophthalmol       Date:  2015-08-17       Impact factor: 1.909

5.  Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery.

Authors:  Young Choi; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  BMC Ophthalmol       Date:  2017-12-28       Impact factor: 2.209

6.  Correlation of binocular refractive error and calculation of intraocular Lens power for the second eye.

Authors:  Pengcheng Zhang; Yuhuan Yang; Hong Yan; Jie Zhang; Weijia Yan
Journal:  BMC Ophthalmol       Date:  2020-06-18       Impact factor: 2.209

7.  Endophthalmitis Rate in Immediately Sequential versus Delayed Sequential Bilateral Cataract Surgery within the Intelligent Research in Sight (IRIS®) Registry Data.

Authors:  Megan Lacy; Timothy-Paul H Kung; Julia P Owen; Ryan T Yanagihara; Marian Blazes; Suzann Pershing; Leslie G Hyman; Russell N Van Gelder; Aaron Y Lee; Cecilia S Lee
Journal:  Ophthalmology       Date:  2021-07-13       Impact factor: 14.277

Review 8.  Surgical options for correction of refractive error following cataract surgery.

Authors:  Ahmed A Abdelghany; Jorge L Alio
Journal:  Eye Vis (Lond)       Date:  2014-10-16

9.  Inter-ocular and inter-visit differences in ocular biometry and refractive outcomes after cataract surgery.

Authors:  Hyun Sup Choi; Hyo Soon Yoo; Yerim An; Sam Young Yoon; Sung Pyo Park; Yong-Kyu Kim
Journal:  Sci Rep       Date:  2020-09-07       Impact factor: 4.379

10.  Disruptive Innovation and Refractive IOLs: How the Game Will Change With Adjustable IOLs.

Authors:  David F Chang
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Nov-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.