Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups.

Martin Gottliebsen1, Ole Rahbek, Per F Ottosen, Kjeld Søballe, Maiken Stilling.   

Abstract

Hydroxyapatite (HA) coating of implant surfaces is believed to improve longevity of uncemented total hip arthroplasty (THA). However; it is speculated that HA particles may cause third body wear of the polyethylene (PE) liner with subsequent osteolysis and aseptic loosening of implants. We performed a retrospective comparison of two patient populations with cementless Mallory-Head acetabular components. The patients were identified in the Danish hip arthroplasty Registry (DHR); 77 patients had HA-coated cups and 73 patients had non-HA coated cups. Anteroposterior (AP) radiographs were analysed for PE wear, osteolysis was quantified and survival of the acetabular components was compared. The mean follow-up was 11 years. There were no cup revisions in the HA group and 7 cup revisions in the non-HA group (P<0.01). The reason for revision in all cases was aseptic loosening of both stem and cup. The amount of osteolysis was significantly increased around cups in the non-HA group. The two-dimensional linear PE wear-rate of 0.18 mm/year was higher (P<0.001) in the group with HA coated cups compared with 0.12 mm/year in the group with non-HA coated cups. The mean age was lower (P=0.001) in the HA group (57 years) compared with the non-HA group (63 years). After 11.1 years of follow-up non-HA coated cups had a higher revision rate. Increased PE wear with HA-coated cups did not have a negative influence on the revision rate, but may result in a need for revision surgery over time.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22383319     DOI: 10.5301/HIP.2012.9075

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  5 in total

1.  No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups.

Authors:  Kestutis Valancius; Kjeld Søballe; Poul T Nielsen; Mogens B Laursen
Journal:  Acta Orthop       Date:  2013-10-31       Impact factor: 3.717

2.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

3.  Dimensional analysis of total hip arthroplasty polyethylenes.

Authors:  Carlos Roberto Schwartsmann; Leandro de Freitas Spinelli; Leonardo Carbonera Boschin; Ramiro Zilles Gonçalves; Anthony Kerbes Yépez; Telmo Roberto Strohaecker; Ralf Wellis de Souza
Journal:  Rev Bras Ortop       Date:  2013-12-19

4.  Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry.

Authors:  Kristian Horsager; Frank Madsen; Anders Odgaard; Claus Fink Jepsen; Lone Rømer; Per Wagner Kristensen; Bart L Kaptein; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2018-12-10       Impact factor: 3.717

5.  Larger 5-year migration but similar polyethylene wear of cementless hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) coating compared with porous plasma-spray titanium: a randomized 5-year RSA study.

Authors:  Sebastian Breddam Mosegaard; Peter Bo Jørgensen; Stig Storgaard Jakobsen; Henrik Daugaard; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2022-07-14       Impact factor: 3.925

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.