Literature DB >> 22383063

Influence of material choice on the force delivery of bimaxillary tooth positioners on canine malpositions.

D Lochmatter1, M Steineck, L Brauchli.   

Abstract

OBJECTIVE: Since their introduction in 1945, tooth positioners have been used to treat a range of malpositions. Although the original appliance was made of natural rubber, today's tooth positioners are fabricated from various elastic, transparent materials. It was the aim of this study to evaluate the forces and moments produced by current positioners on various upper canine malpositions.
MATERIAL AND METHODS: Seven positioners of different materials were tested on 11 upper canine malpositions: 0.25, 0.5, 1 mm supraposition; 0.25, 0.5, 1 mm infraposition; 5°, 10°, 20° mesiorotation; 5° mesioinclination, 5° buccal root torque. We measured forces and moments in vitro after bite closure by 0.5 mm, and opening by 1 mm using a three-dimensional robotic device. All measurements were taken in a temperature-controlled environment at 36 °C.
RESULTS: The forces and moments measured at the canine varied greatly among the different positioners, with the thermoformed EVA positioner showing much greater forces and moments in almost all malpositions. At initial closure, we observed intrusive forces of 6-32 N for suprapositions, 0-11 N intrusive forces for infrapositions, 0-20 Nmm for mesiorotations, 6-12 Nmm for mesioinclinations, and - 23 Nmm to 5 Nmm for buccal root torque. All positioners were most effective on suprapositioned teeth. Very low or negligible correctional forces and moments in conjunction with all infrapositions and 5° with rotation were noted. Labial root torque led to unpredictable moments.
CONCLUSION: Positioner material plays a major role in delivering forces to the teeth. However, tooth positioners did not induce corrective forces in all the malpositions tested. Clinically relevant correctional forces or moments in conjunction with all suprapositions, rotations of 10° and 20° as well as mesial tipping of the canine were observed.

Entities:  

Mesh:

Year:  2012        PMID: 22383063     DOI: 10.1007/s00056-011-0067-7

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  16 in total

1.  Short-term, intensive use of the tooth positioner in case finishing.

Authors:  S Jay Bowman; Aldo Carano
Journal:  J Clin Orthod       Date:  2002-04

2.  Dynamic functional force measurements on an anterior bite plane during the night.

Authors:  Andrea Wichelhaus; Stefan Hüffmeier; Franz-Günter Sander
Journal:  J Orofac Orthop       Date:  2003-11       Impact factor: 1.938

3.  Some observations on the history and uses of the Kesling positioner.

Authors:  W A ELSASSER
Journal:  Am J Orthod       Date:  1950-05

4.  Physical and mechanical properties of elastomers in orthodontic positioners.

Authors:  S P Warunek; S E Sorensen; J J Cunat; L J Green
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-05       Impact factor: 2.650

5.  Evaluation of polymeric materials for maxillofacial prosthetics.

Authors:  D J Moore; Z R Glaser; M J Tabacco; M G Linebaugh
Journal:  J Prosthet Dent       Date:  1977-09       Impact factor: 3.426

6.  Application of the positioner appliance in orthodontic treatment.

Authors:  N E Wells
Journal:  Am J Orthod       Date:  1970-10

7.  Physical properties of materials for custom-made mouth protectors.

Authors:  R G Craig; W C Godwin
Journal:  J Mich State Dent Assoc       Date:  1967-02

8.  Relationship between tooth-movement rate and estimated pressure applied.

Authors:  B W Lee
Journal:  J Dent Res       Date:  1965 Sep-Oct       Impact factor: 6.116

9.  [The force transmission of positioners in different degrees of incisor protrusion. An in-vitro study].

Authors:  D Rost; C W Schwarze; R D Hilgers
Journal:  Fortschr Kieferorthop       Date:  1995-03

10.  Case reports on tooth positioners using LTV vinyl silicone rubber.

Authors:  K Kamada; T Tamura; Y Hama; T Koike; T Kanda; M Takahashi; Y Nagata; M Nishiyama
Journal:  J Nihon Univ Sch Dent       Date:  1984-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.