Literature DB >> 22382087

Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer.

Piernicola Pedicini1, Rocchina Caivano, Alba Fiorentino, Lidia Strigari, Giorgia Califano, Viviana Barbieri, Piero Sanpaolo, Giovanni Castaldo, Marcello Benassi, Vincenzo Fusco.   

Abstract

To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose on PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d(2cc), d(1cc), and d(max) (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.
Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22382087     DOI: 10.1016/j.meddos.2011.11.009

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  What is the best way to evaluate clinical target volume for radiotherapy of brain tumors?

Authors:  Alba Fiorentino; Piernicola Pedicini; Rocchina Caivano; Vincenzo Fusco
Journal:  CNS Oncol       Date:  2013-11

2.  The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

Authors:  R Caivano; A Fiorentino; P Pedicini; G Califano; V Fusco
Journal:  Clin Transl Oncol       Date:  2013-09-20       Impact factor: 3.405

3.  Do comorbidity influences acute toxicity and outcome in elderly patients with endometrial cancer treated by adjuvant radiotherapy plus brachytherapy?

Authors:  A Fiorentino; C Chiumento; V Fusco
Journal:  Clin Transl Oncol       Date:  2013-01-29       Impact factor: 3.405

Review 4.  Vaginal cuff brachytherapy in endometrial cancer - a technically easy treatment?

Authors:  Sebastià Sabater; Ignacio Andres; Veronica Lopez-Honrubia; Roberto Berenguer; Marimar Sevillano; Esther Jimenez-Jimenez; Angeles Rovirosa; Meritxell Arenas
Journal:  Cancer Manag Res       Date:  2017-08-09       Impact factor: 3.989

5.  Local tumor control probability to evaluate an applicator-guided volumetric-modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer.

Authors:  Piernicola Pedicini; Lidia Strigari; Rocchina Caivano; Alba Fiorentino; Giorgia Califano; Antonio Nappi; Giuseppina Improta; Giovanni Storto; Mariella Cozzolino; Costanza Chiumento; Vincenzo Fusco; Andrea Vavassori; Marcello Benassi; Roberto Orecchia; Marco Salvatore
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

Review 6.  The value of brachytherapy in the age of advanced external beam radiotherapy: a review of the literature in terms of dosimetry.

Authors:  Tibor Major; Georgina Fröhlich; Péter Ágoston; Csaba Polgár; Zoltán Takácsi-Nagy
Journal:  Strahlenther Onkol       Date:  2021-11-01       Impact factor: 3.621

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.