Literature DB >> 22381925

Analysis of maximum P-wave duration and dispersion after percutaneous closure of atrial septal defects: comparison of two septal occluders.

Feyza Ayşenur Paç1, Sevket Balli, Serkan Topaloğlu, Ibrahim Ece, Mehmet Burhan Oflaz.   

Abstract

OBJECTIVE: Amplatzer septal occluder (ASO) is the most widely used device for closure of atrial septal defect (ASD). Figulla septal occluder (FSO) is a similar device to ASO with some structural innovations. The aim of study is to assess the maximum P-wave duration (Pmax) and dispersion (Pd) in patients who underwent ASD closure with both devices, to determine the effects of structural innovations on atrial electrical inhomogeneity.
METHODS: The study is a retrospective cohort analysis. Between December 2005 and March 2010, 121 patients underwent percutaneous closure of secundum ASD were included in this study. FSO was used in 79 patients, ASO in 42 patients. Pmax and Pd were measured on the surface electrocardiography before and soon after procedure. For comparison of P-wave parameters initially and after procedure paired t-test was used. Correlation analysis was performed using Pearson correlation test.
RESULTS: Pmax and Pd were significantly increased immediate after procedure (p<0.001). In FSO and ASO group pre/postprocedural Pd were 38.3 ± 2.7/ 44.1 ± 2.7 msec and 37.5 ± 2.5/ 50.1 ± 2.2 msec respectively. ASO group had a greater postprocedural Pmax and Pd (p<0.001). Left and right atrial disc diameter and device size were the strongest correlates of Pd (r=0.52, p<0.001; r=0.58, p<0.001; r=0.35, p=0.001, respectively). Moderate correlation was found between pre-intervention Pd and age (p=0.008).
CONCLUSIONS: Pmax and Pd were significantly increased soon after atrial septal defect closure procedure in both devices. Pd is significantly lower in patients closed with FSO device. Difference may be due to the distinctive texture of devices. There was no significant difference in terms of clinically apparent arrhythmia after closure with both device types.

Entities:  

Mesh:

Year:  2012        PMID: 22381925     DOI: 10.5152/akd.2012.069

Source DB:  PubMed          Journal:  Anadolu Kardiyol Derg        ISSN: 1302-8723


  6 in total

1.  Longitudinal evaluation of P-wave dispersion and P-wave maximum in children after transcatheter device closure of secundum atrial septal defect.

Authors:  Robert Teodoro Grignani; Kim Martin Tolentino; Dimple Dayaram Rajgor; Swee Chye Quek
Journal:  Pediatr Cardiol       Date:  2015-01-28       Impact factor: 1.655

2.  Comparison of the early cardiac electromechanical remodeling following transcatheter and surgical secundum atrial septal defect closure in adults.

Authors:  Amr Mansour; Noha M Gamal; M Alaa Nady; Salwa R Demitry; H Shams-Eddin; Khaled M El-Maghraby
Journal:  Egypt Heart J       Date:  2021-06-10

3.  Comparison of primary repair and patch plasty procedure on the P wave in adult atrial septal defect closure.

Authors:  Alper Ucak; Veysel Temizkan; Murat Ugur; Ahmet Erturk Yedekci; Omer Uz; Arif Selcuk; Ahmet Turan Yilmaz
Journal:  Cardiovasc J Afr       Date:  2016-05-04       Impact factor: 1.167

4.  Holter electrocardiography findings and P-wave dispersion in pediatric patients with transcatheter closure of atrial septal defects.

Authors:  Isa Ozyilmaz; Sinem Ozyilmaz; Hasan Tahsin Tola; Murat Saygi; Neslihan Kiplapinar; Cansaran Tanıdır; Yakup Ergul; Alper Guzeltas; Ender Odemis
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-10-08       Impact factor: 1.468

5.  The Effect of Synthetic Cannabinoids on P-Wave Dispersion: An Observational Study.

Authors:  Esra Aydin Sunbul; Murat Sunbul; Ayse Terzi; Sumeyye Calli; Esra Koca; Rabia Bilici; Serhat Citak
Journal:  Med Princ Pract       Date:  2016-06-10       Impact factor: 1.927

6.  Immediate and short term effects of percutaneous atrial septal defect device closure on cardiac electrical remodeling in children.

Authors:  Alaa Mahmoud Roushdy; Hebatalla Attia; Heba Nossir
Journal:  Egypt Heart J       Date:  2018-03-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.