Abstract

OBJECTIVE: To report a novel technique for temporary and permanent vessel occlusion with a single microcatheter and investigate its efficacy in endovascular management of cerebral aneurysms and invasive head and neck tumors.
METHODS: A 58-year-old woman with a history of T3N0 squamous cell carcinoma of the tongue with extensive surgical resections and radiotherapy presented to the emergency department with further wound dehiscence and exposure of the left cervical internal carotid artery (ICA). Digital subtraction angiography (DSA) was performed with the patient under conscious sedation. An Ascent balloon, 4 mm × 15 mm, was prepared and introduced into the proximal ICA. While the patient was fully awake, temporary balloon occlusion (TBO) was performed for 30 minutes. The Ascent balloon was kept inflated. Through the inflated Ascent balloon, coil embolization of the proximal ICA was initiated. The interstices of the coils were filled with Onyx 18 and Onyx 34 liquid embolic agents (ev3 Neurovascular, Inc, Irvine, California, USA).
RESULTS: The Ascent balloon can be used as a temporary balloon device and as a coil or Onyx embolization device. As a result, fewer catheters, guidewires, and balloon inflations and deflations are required for the procedure, which is both cost-effective and time-efficient. The combination of initial coiling to create a framework for the deconstruction with a liquid embolic agent (Onyx) is a safe and efficient technique for vessel deconstruction. Flow arrest with proximal balloon occlusion minimizes the risks of distal thromboembolic events during embolization.
CONCLUSIONS: This novel technique for temporary and permanent vessel occlusion with a single microcatheter is both cost-effective and time-efficient.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22381875     DOI: 10.1016/j.wneu.2012.01.032

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  2 in total

1.  Carotid and vertebral artery sacrifice with a combination of Onyx and coils: technical note and case series.

Authors:  Nohra Chalouhi; Robert M Starke; Stavropoula I Tjoumakaris; Pascal M Jabbour; L Fernando Gonzalez; David Hasan; Robert H Rosenwasser; Aaron S Dumont
Journal:  Neuroradiology       Date:  2013-05-16       Impact factor: 2.804

2.  Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

Authors:  Frédéric Clarençon; Aurelien Nouet; Aimée Redondo; Federico Di Maria; Christina Iosif; Lise Le Jean; Jacques Chiras; Nader Sourour
Journal:  BMJ Case Rep       Date:  2013-05-31