Literature DB >> 22381739

Prestress as an optimal biomechanical parameter for needle penetration.

Kent D Butz1, Adam J Griebel, Tyler Novak, Kevin Harris, Amy Kornokovich, Michael F Chiappetta, Corey P Neu.   

Abstract

Drug delivery requires precise intradermal and subcutaneous injections of formulations to clinically relevant penetration depths. However, penetration depth is confounded by skin deflection, which occurs prior to and during penetration as the skin surface deforms axially with the needle, and which varies profoundly due to differing intrinsic mechanical (e.g. viscoelastic) tissue properties, disease state, aging, and ethnicity. Herein, an ex vivo model was utilized to study factors that affect skin deflection and the efficacy of injection, including prestress applied at the tissue surface, needle gauge, velocity, and actuation depth. The application of prestress minimized skin deflection during needle penetration and allowed for needle actuation to the targeted penetration depths with minimum variability. The force required to achieve target penetration depths was found to increase with prestress and decrease with needle gauge. Our findings emphasize the need for prestress applied to the skin surface to minimize variation in skin properties and administer formulations for intradermal and subcutaneous treatments with maximum precision.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2012        PMID: 22381739     DOI: 10.1016/j.jbiomech.2012.01.049

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

Review 1.  Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

Authors:  Pan Li; Zhiyong Yang; Shan Jiang
Journal:  Med Biol Eng Comput       Date:  2018-04-21       Impact factor: 2.602

2.  Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results.

Authors:  Jana Steger; Isabella Patzke; Maximilian Berlet; Stefanie Ficht; Markus Eblenkamp; Petra Mela; Dirk Wilhelm
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-23       Impact factor: 3.421

3.  Bioinspired Rotation Microneedles for Accurate Transdermal Positioning and Ultraminimal-Invasive Biomarker Detection with Mechanical Robustness.

Authors:  Yilin Cai; Shiyi Huang; Zhinan Zhang; Jiazheng Zhang; Xingyue Zhu; Xiaoxiang Chen; Xianting Ding
Journal:  Research (Wash D C)       Date:  2022-03-07

Review 4.  Application of microneedle patches for drug delivery; doorstep to novel therapies.

Authors:  Fateme Nazary Abrbekoh; Leila Salimi; Sepideh Saghati; Hassan Amini; Sonia Fathi Karkan; Keyvan Moharamzadeh; Emel Sokullu; Reza Rahbarghazi
Journal:  J Tissue Eng       Date:  2022-04-29       Impact factor: 7.940

5.  Nuclear Stiffness Decreases with Disruption of the Extracellular Matrix in Living Tissues.

Authors:  Kaitlin P McCreery; Xin Xu; Adrienne K Scott; Apresio K Fajrial; Sarah Calve; Xiaoyun Ding; Corey P Neu
Journal:  Small       Date:  2021-01-20       Impact factor: 13.281

Review 6.  Engineering Microneedle Patches for Improved Penetration: Analysis, Skin Models and Factors Affecting Needle Insertion.

Authors:  Aaron R J Hutton; Majid Shabani; Cynthia K Y Yiu; Zahra Baghbantaraghdari; Rezvan Jamaledin; Marco Carlotti; Barbara Mazzolai; Pooyan Makvandi; Melissa Kirkby; Virgilio Mattoli; Ryan F Donnelly
Journal:  Nanomicro Lett       Date:  2021-03-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.