Literature DB >> 22381371

Characteristics of third-generation glucose biosensors based on Corynascus thermophilus cellobiose dehydrogenase immobilized on commercially available screen-printed electrodes working under physiological conditions.

Muhammad Nadeem Zafar1, Gulnara Safina, Roland Ludwig, Lo Gorton.   

Abstract

In this article, we describe a third-generation amperometric glucose biosensor working under physiological conditions. This glucose biosensor consists of a recently discovered cellobiose dehydrogenase from the ascomycete Corynascus thermophilus (CtCDH) immobilized on different commercially available screen-printed electrodes made of carbon (SPCEs), carboxyl-functionalized single-walled carbon nanotubes (SPCE-SWCNTs), or multiwalled carbon nanotubes (SPCE-MWCNTs) by simple physical adsorption or a combination of adsorption followed by cross-linking using poly(ethyleneglycol) (400) diglycidyl ether (PEGDGE) or glutaraldehyde (GA). The CtCDH-based third-generation glucose biosensor has a linear range between 0.025 and 30 mM and a detection limit of 10 μM glucose. Biosensors based on SWCNTs showed a higher sensitivity and catalytic response than the ones functionalized with MWCNTs and the SPCEs. A drastic increase in response was observed for all three electrodes when the adsorbed enzyme was cross-linked with PEGDGE or GA. The operational stability of the biosensor was tested for 7 h by repeated injections of 50 mM glucose, and only a slight decrease in the electrochemical response was found. The selectivity of the CtCDH-based biosensor was tested on other potentially interfering carbohydrates such as mannose, galactose, sucrose, and fucose that might be present in blood. No significant analytical response from any of these compounds was observed.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22381371     DOI: 10.1016/j.ab.2012.02.026

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  9 in total

1.  Studying direct electron transfer by site-directed immobilization of cellobiose dehydrogenase.

Authors:  Marta Meneghello; Firas A Al-Lolage; Su Ma; Roland Ludwig; Philip N Bartlett
Journal:  ChemElectroChem       Date:  2019-01-30       Impact factor: 4.590

Review 2.  Cellobiose dehydrogenase modified electrodes: advances by materials science and biochemical engineering.

Authors:  Roland Ludwig; Roberto Ortiz; Christopher Schulz; Wolfgang Harreither; Christoph Sygmund; Lo Gorton
Journal:  Anal Bioanal Chem       Date:  2013-01-18       Impact factor: 4.142

3.  Substrate specificity and interferences of a direct-electron-transfer-based glucose biosensor.

Authors:  Alfons K G Felice; Christoph Sygmund; Wolfgang Harreither; Roman Kittl; Lo Gorton; Roland Ludwig
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

4.  Optimization of production, purification and lyophilisation of cellobiose dehydrogenase by Sclerotium rolfsii.

Authors:  Christin Fischer; Annett Krause; Thomas Kleinschmidt
Journal:  BMC Biotechnol       Date:  2014-11-19       Impact factor: 2.563

5.  Self-powered wireless carbohydrate/oxygen sensitive biodevice based on radio signal transmission.

Authors:  Magnus Falk; Miguel Alcalde; Philip N Bartlett; Antonio L De Lacey; Lo Gorton; Cristina Gutierrez-Sanchez; Raoudha Haddad; Jeremy Kilburn; Dónal Leech; Roland Ludwig; Edmond Magner; Diana M Mate; Peter Ó Conghaile; Roberto Ortiz; Marcos Pita; Sascha Pöller; Tautgirdas Ruzgas; Urszula Salaj-Kosla; Wolfgang Schuhmann; Fredrik Sebelius; Minling Shao; Leonard Stoica; Cristoph Sygmund; Jonas Tilly; Miguel D Toscano; Jeevanthi Vivekananthan; Emma Wright; Sergey Shleev
Journal:  PLoS One       Date:  2014-10-13       Impact factor: 3.240

6.  A Third Generation Glucose Biosensor Based on Cellobiose Dehydrogenase Immobilized on a Glassy Carbon Electrode Decorated with Electrodeposited Gold Nanoparticles: Characterization and Application in Human Saliva.

Authors:  Paolo Bollella; Lo Gorton; Roland Ludwig; Riccarda Antiochia
Journal:  Sensors (Basel)       Date:  2017-08-18       Impact factor: 3.576

Review 7.  Biosensors in clinical practice: focus on oncohematology.

Authors:  Nicola S Fracchiolla; Silvia Artuso; Agostino Cortelezzi
Journal:  Sensors (Basel)       Date:  2013-05-14       Impact factor: 3.576

Review 8.  Biosensors in clinical chemistry: An overview.

Authors:  Sathish Babu Murugaiyan; Ramesh Ramasamy; Niranjan Gopal; V Kuzhandaivelu
Journal:  Adv Biomed Res       Date:  2014-01-27

Review 9.  Direct Electron Transfer of Dehydrogenases for Development of 3rd Generation Biosensors and Enzymatic Fuel Cells.

Authors:  Paolo Bollella; Lo Gorton; Riccarda Antiochia
Journal:  Sensors (Basel)       Date:  2018-04-24       Impact factor: 3.576

  9 in total