Right intercostal insertion of a Veress needle for laparoscopy in dogs.

Valentina Fiorbianco1, Monika Skalicky, Judith Doerner, Murat Findik, Gilles Dupré.   

Abstract

OBJECTIVE: To evaluate right intercostal Veress needle (VN) insertion for laparoscopy in dogs. STUDY
DESIGN: Longitudinal cohort study. ANIMALS: Female dogs (n = 56).
METHODS: The VN was inserted in the last palpable right intercostal space, either 1/3 (Group T; 28 dogs) or mid distance (Group H; 28 dogs) from the xiphoid cartilage to the most caudal extent of the costal arch. Problems encountered during VN insertion and injuries were recorded, graded, and compared between groups, and also between the first and last 20 insertions.
RESULTS: Pneumoperitoneum was successfully achieved by VN insertion in 49 (88%) dogs after a single (45 dogs) or 2nd attempt (4 dogs). Frequency of complications was as follows: 20 grade 1 (subcutaneous emphysema, omentum, or falciform injuries); 6 grade 2 (liver or spleen injury), and 1 grade 3 complication (pneumothorax occurred). No significant difference was found between the 2 groups or between the first and last 20 dogs.
CONCLUSIONS: Right intercostal VN insertion facilitates pneumoperitoneum in dogs with few consequential complications. No significant difference was found between entry sites; however, the mid distance insertion site in the last palpable intercostal space with dog positioned in dorsal recumbency is likely to result in less complications. © Copyright 2012 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Year:  2012        PMID: 22380700     DOI: 10.1111/j.1532-950X.2012.00961.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  3 in total

1.  Laparoscopic ovariectomy in dogs: comparison between laparoendoscopic single-site and three-portal access.

Authors:  Angelo E Tapia-Araya; Idoia Díaz-Güemes Martin-Portugués; Laura Fresno Bermejo; Francisco Miguel Sánchez-Margallo
Journal:  J Vet Sci       Date:  2015       Impact factor: 1.672

2.  Bilateral medial iliac lymph node excision by a ventral laparoscopic approach: technique description.

Authors:  Hyunjoo Lim; Jina Kim; Li Li; Aeri Lee; Junemoe Jeong; Jonghyeok Ko; Sungin Lee; Oh-Kyeong Kweon; Wan Hee Kim
Journal:  J Vet Med Sci       Date:  2017-08-04       Impact factor: 1.267

3.  Influence of 2 Veress needles and 4 insertion sites on Veress needle penetration depth: A comparative study in cadaveric dogs.

Authors:  Katharina Leschnik; Barbara Bockstahler; Nikola Katic; Johannes P Schramel; Gilles Dupré
Journal:  Vet Surg       Date:  2018-09-23       Impact factor: 1.495