Literature DB >> 22377953

The reliability of lower extremity and thoracic kinematics at various running speeds.

K Doma1, G B Deakin, R M Sealey.   

Abstract

Whilst various studies have examined lower extremity joint kinematics during running, there is limited investigation on joint kinematics at steady-state running and at intensities close to exhaustion. Subsequently, the purpose of this study was to determine whether the reliability of kinematics in the lower extremity and thorax is affected by varying the running speeds during a running economy test. 14 trained and moderately trained runners undertook 2 running economy tests with each test incorporating 3 intensity stages: 70-, 90- and 110% of the second ventilatory threshold, respectively. The participants ran for 10 min during each of the first 2 stages and to exhaustion during the last stage. Kinematics of the ankle, knee, hip, pelvis and thorax were recorded using a 3-dimensional motion analysis system. Intra-class correlation coefficient (ICC), limits of agreement (LOA) and coefficient of variation (CV) were used to calculate reliability. The ICC, LOA and CV of the lower extremity and thoracic kinematic variables ranged from 0.33-0.97, 1.03-1.39 and 2.0-18.6, respectively. Whilst the reliability did vary between the kinematic variables, the majority of results showed minimal within-subject variation and moderate to high reliability. In conclusion, examining thoracic and lower extremity kinematics is useful in determining whether running kinematics is altered with varying running intensities. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 22377953     DOI: 10.1055/s-0031-1299751

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  3 in total

1.  The repeated bout effect of typical lower body strength training sessions on sub-maximal running performance and hormonal response.

Authors:  Kenji Doma; Moritz Schumann; Wade H Sinclair; Anthony S Leicht; Glen B Deakin; Keijo Häkkinen
Journal:  Eur J Appl Physiol       Date:  2015-04-01       Impact factor: 3.078

2.  Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of "freehand" to "probe force device" method of real-time ultrasound imaging.

Authors:  Vanessa L Kennedy; Carol A Flavell; Kenji Doma
Journal:  Ultrasound       Date:  2019-02-25

3.  RELIABILITY OF TWO-DIMENSIONAL VIDEO-BASED RUNNING GAIT ANALYSIS.

Authors:  Mark F Reinking; Leigh Dugan; Nolan Ripple; Karen Schleper; Henry Scholz; Jesse Spadino; Cameron Stahl; Thomas G McPoil
Journal:  Int J Sports Phys Ther       Date:  2018-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.