Short-term versus long-term rainfall time series in the assessment of potable water savings by using rainwater in houses.

Enedir Ghisi1, Karla Albino Cardoso, Ricardo Forgiarini Rupp.   

Abstract

The main objective of this article is to assess the possibility of using short-term instead of long-term rainfall time series to evaluate the potential for potable water savings by using rainwater in houses. The analysis was performed considering rainfall data from 1960 to 1995 for the city of Santa Bárbara do Oeste, located in the state of São Paulo, southeastern Brazil. The influence of the rainfall time series, roof area, potable water demand and percentage rainwater demand on the potential for potable water savings was evaluated. The potential for potable water savings was estimated using computer simulations considering a set of long-term rainfall time series and different sets of short-term rainfall time series. The ideal rainwater tank capacity was also assessed for some cases. It was observed that the higher the percentage rainwater demand and the shorter the rainfall time series, the larger the difference between the potential for potable water savings and the greater the variation in the ideal rainwater tank size. The sets of short-term rainfall time series considered adequate for different scenarios ranged from 1 to 13 years depending on the roof area, percentage rainwater demand and potable water demand. The main finding of the research is that sets of short-term rainfall time series can be used to assess the potential for potable water savings by using rainwater, as the results obtained are similar to those obtained from the long-term rainfall time series.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22377369     DOI: 10.1016/j.jenvman.2011.12.031

Source DB:  PubMed          Journal:  J Environ Manage        ISSN: 0301-4797            Impact factor:   6.789


  2 in total

1.  Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

Authors:  Vitor Sousa; Cristina Matos Silva; Inês C Meireles
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-10       Impact factor: 4.223

2.  Development of a HEC-HMS-based watershed modeling system for identification, allocation, and optimization of reservoirs in a river basin.

Authors:  R Srinivas; Ajit Pratap Singh; Anirban Deshmukh
Journal:  Environ Monit Assess       Date:  2017-12-19       Impact factor: 2.513

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.