Literature DB >> 22374825

An evaluation of the DRI-ETG EIA method for the determination of ethyl glucuronide concentrations in clinical and post-mortem urine.

Sophie C Turfus1, Tu Vo, Nadia Niehaus, Dimitri Gerostamoulos, Jochen Beyer.   

Abstract

A commercial enzyme immunoassay for the qualitative and semi-quantitative measurement of ethyl glucuronide (EtG) in urine was evaluated. Post-mortem (n=800), and clinical urine (n=200) samples were assayed using a Hitachi 902 analyzer. The determined concentrations were compared with those obtained using a previously published liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of EtG and ethyl sulfate. Using a cut-off of 0.5 µg/ml and LC-MS/MS limit of reporting of 0.1 µg/ml, there was a sensitivity of 60.8% and a specificity of 100% for clinical samples. For post-mortem samples, sensitivity and specificity were 82.4% and 97.1%, respectively. When reducing the cut-off to 0.1 µg/ml, the sensitivity and specificity were 83.3% and 100% for clinical samples whereas for post-mortem samples the sensitivity and specificity were 90.3 % and 88.3 %, respectively. The best trade-offs between sensitivity and specificity for LC-MS/MS limits of reporting of 0.5 and 0.1 µg/ml were achieved when using immunoassay cut-offs of 0.3 and 0.092 µg/ml, respectively. There was good correlation between quantitative results obtained by both methods but analysis of samples by LC-MS/MS gave higher concentrations than by enzyme immunoassay (EIA), with a statistically significant proportional bias (P<0.0001, Deming regression) for both sample types. The immunoassay is reliable for the qualitative and semi-quantitative presumptive detection of ethyl glucuronide in urine.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22374825     DOI: 10.1002/dta.414

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  5 in total

Review 1.  Biomarkers for detection of alcohol consumption in liver transplantation.

Authors:  Katharina Staufer; Michel Yegles
Journal:  World J Gastroenterol       Date:  2016-04-14       Impact factor: 5.742

2.  High Agreement Between Benchtop and Point-of-Care Dipcard Tests for Ethyl Glucuronide.

Authors:  Emily Leickly; Jordan Skalisky; Sterling McPherson; Michael F Orr; Michael G McDonell
Journal:  Ther Drug Monit       Date:  2017-08       Impact factor: 3.681

3.  High levels of agreement between clinic-based ethyl glucuronide (EtG) immunoassays and laboratory-based mass spectrometry.

Authors:  Emily Leickly; Michael G McDonell; Roger Vilardaga; Frank A Angelo; Jessica M Lowe; Sterling McPherson; Debra Srebnik; John M Roll; Richard K Ries
Journal:  Am J Drug Alcohol Abuse       Date:  2015-02-19       Impact factor: 3.829

4.  Ethyl glucuronide and ethyl sulfate assays in clinical trials, interpretation, and limitations: results of a dose ranging alcohol challenge study and 2 clinical trials.

Authors:  Peter I Jatlow; Ann Agro; Ran Wu; Haleh Nadim; Benjamin A Toll; Elizabeth Ralevski; Christine Nogueira; Julia Shi; James D Dziura; Ismene L Petrakis; Stephanie S O'Malley
Journal:  Alcohol Clin Exp Res       Date:  2014-04-28       Impact factor: 3.455

Review 5.  Biomolecules and Biomarkers Used in Diagnosis of Alcohol Drinking and in Monitoring Therapeutic Interventions.

Authors:  Radu M Nanau; Manuela G Neuman
Journal:  Biomolecules       Date:  2015-06-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.