Literature DB >> 22373035

Wavefront ablation profiles in refractive surgery: description, results, and limitations.

David Smadja1, Glauco Reggiani-Mello, Marcony R Santhiago, Ronald R Krueger.   

Abstract

PURPOSE: To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations.
METHODS: Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes.
RESULTS: Over the past 10 years, a large number of studies comparing different treatment algorithms and newer excimer laser platforms have been published. Thirty-six clinical studies including 3637 eyes analyzing the clinical results obtained after wavefront-guided, wavefront-optimized, and Q-factor profiles have been reviewed. Although wavefront-driven profiles allowed reduction of the amount of induced optical aberrations with conventional ablations, thereby improving the quality of vision, it appears that no algorithm of treatment or excimer laser platform has demonstrated a clear superiority over another. Wound healing and unexpected biomechanical response to surgery affect the accuracy of customized treatments and produce variable results. In addition, it is difficult to rigorously analyze and compare findings among different studies because of the diverse variety in which the data are reported.
CONCLUSIONS: Despite several technological improvements over the years, wavefront ablation profiles have not consistently demonstrated superiority in terms of visual acuity and lower order aberrations compared to the standard procedure, although the induction of higher order aberrations has been reduced. The concept of an individualized eye model has emerged recently, based on the optical ray tracing algorithm, and could theoretically provide a higher level of customization, thus fulfilling the promise of "super vision." Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22373035     DOI: 10.3928/1081597X-20120217-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  19 in total

1.  Effect of Iris registration on visual outcome in wavefront-guided LASEK for myopic astigmatism.

Authors:  Jong Joo Lee; Mee Kum Kim; Won Ryang Wee
Journal:  Int Ophthalmol       Date:  2017-03-11       Impact factor: 2.031

2.  Comparing aspheric ablation profile with standard corneal ablation for correction of myopia and myopic astigmatism, a contralateral eye study.

Authors:  Mohammad Ghoreishi; Afsaneh Naderi Beni; Zahra Naderi Beni; Alireza Zandi; Farzan Kianersi
Journal:  Lasers Med Sci       Date:  2017-10-23       Impact factor: 3.161

3.  Wavefront excimer laser refractive surgery for adults with refractive errors.

Authors:  Shi-Ming Li; Meng-Tian Kang; Ning-Li Wang; Samuel A Abariga
Journal:  Cochrane Database Syst Rev       Date:  2020-12-18

Review 4.  Refractive surgery beyond 2020.

Authors:  Marcus Ang; Damien Gatinel; Dan Z Reinstein; Erik Mertens; Jorge L Alió Del Barrio; Jorge L Alió
Journal:  Eye (Lond)       Date:  2020-07-24       Impact factor: 3.775

5.  Wavefront-optimized surface retreatments of refractive error following previous laser refractive surgery: a retrospective study.

Authors:  Kevin M Broderick; Rose K Sia; Denise S Ryan; Richard D Stutzman; Michael J Mines; Travis C Frazier; Mark F Torres; Kraig S Bower
Journal:  Eye Vis (Lond)       Date:  2016-02-11

6.  Image Quality Analysis of Eyes Undergoing LASER Refractive Surgery.

Authors:  Samrat Sarkar; Pravin Krishna Vaddavalli; Shrikant R Bharadwaj
Journal:  PLoS One       Date:  2016-02-09       Impact factor: 3.240

7.  Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-02-21

8.  Refractive surgery today: is there innovation or stagnation?

Authors:  Jorge Alio
Journal:  Eye Vis (Lond)       Date:  2014-10-16

9.  Biomechanics of the cornea evaluated by spectral analysis of waveforms from ocular response analyzer and Corvis-ST.

Authors:  Sushma Tejwani; Rohit Shetty; Mathew Kurien; Shoruba Dinakaran; Arkasubhra Ghosh; Abhijit Sinha Roy
Journal:  PLoS One       Date:  2014-08-27       Impact factor: 3.240

10.  Correlation of higher order aberrations and components of astigmatism in myopic refractive surgery candidates.

Authors:  Mehrdad Mohammadpour; Zahra Heidari; Hossein Mohammad-Rabei; Ebrahim Jafarzadehpur; Mahmoud Jabbarvand; Hassan Hashemi; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2016-06-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.