Literature DB >> 22373034

Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.

Jan M Vetter1, Carsten Holtz, Urs Vossmerbaeumer, Norbert Pfeiffer.   

Abstract

PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome.
METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography prior to applanation, during applanation, as well as during and after intrastromal dissection at 450-μm corneal depth. The posterior surface and the dissection line were evaluated for irregularity by fitting a second-order polynomial curve using regression analysis and obtaining the root-mean-square error (RMSE). Groups were compared using analysis of variance.
RESULTS: The RMSE of the posterior surface prior to applanation was 9.7 ± 3.1 μm in the FS laser group and 10.2 ± 2.3 μm in the microkeratome group. The RMSE increased to 50.7 ± 9.4 μm and 20.9 ± 6.1 μm during applanation and decreased again to 10.6 ± 1.4 μm and 8.1 ± 1.8 μm after applanation in the FS laser and microkeratome groups, respectively. The RMSE of the intrastromal cut was 19.5 ± 5.7 μm in the FS laser group and 7.7 ± 3.0 μm in the microkeratome group (P<.001).
CONCLUSIONS: Our results show significantly greater irregularity with the curved interface femtosecond laser-assisted cleavage compared to microkeratome-assisted corneal dissection, possibly due to applanation-derived deformation of the posterior cornea. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22373034     DOI: 10.3928/1081597X-20120208-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty.

Authors:  Chenxing Zhang; Matthew Bald; Maolong Tang; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2015-03-04       Impact factor: 3.351

2.  Changes in asphericity of anterior and posterior corneal surfaces for mild-moderate and high myopia after topography-guided FS-LASIK.

Authors:  Yuan Wu; Shengshu Sun; Zhanglin Liu; Shuhan Wang; Guiqin Wang; Shaozhen Zhao; Ruihua Wei; Yue Huang
Journal:  Int Ophthalmol       Date:  2022-05-30       Impact factor: 2.029

3.  Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas.

Authors:  Chenxing Zhang; Liang Liu; Maolong Tang; Yan Li; Winston Chamberlain; David Huang
Journal:  Cornea       Date:  2015-11       Impact factor: 2.651

Review 4.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

Review 5.  Descemet stripping automated endothelial keratoplasty.

Authors:  Namrata Sharma; Prafulla K Maharana; Shipra Singhi; Neelima Aron; Mukesh Patil
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

6.  Femtosecond laser semi-assisted Descemet stripping endothelial keratoplasty: 2-year outcomes of endothelial cell loss and graft survival.

Authors:  Ting Wang; Peiyan Shi; Fengjie Li; Hua Gao; Suxia Li; Tong Liu; Weiyun Shi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-08-31       Impact factor: 3.117

7.  Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis.

Authors:  Jens Heichel; Frank Wilhelm; Kathleen S Kunert; Rabea Schlueter; Ute Stuhltraeger; Thomas Hammer
Journal:  Clin Ophthalmol       Date:  2013-12-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.