Literature DB >> 2237265

Accuracy of pulse oximetry during moderate exercise: a comparative study.

J C Barthélémy1, A Geyssant, J Riffat, A Antoniadis, J Berruyer, J R Lacour.   

Abstract

This study was designed to discriminate, according to their accuracy, between eight pulse oximeters (PO) using a realistic evaluation performed by means of a moderate exercise to provide artefacts and thus represent a typical clinical situation. Accuracy was assessed by calculating error on saturation (EOS) as the difference between simultaneous measurement of non-invasive (SpO2) and invasive functional (SfO2) arterial blood oxygen saturation. An index of homogeneity of EOS (InH), calculated using a Lehmann analysis, was chosen as a representative of error dispersion, leading to a statistical classification; the influence on error introduced by the drift of EOS with SfO2 was thus eliminated. We obtained a clear-cut separation of the eight PO (Datex Satlite (DA), Kontron 7840 (KO), Nellcor 200 (NE), Novametrix 505 (NO), Ohmeda 3700 (OH), PPG-Hellige (PP), Physiocontrol 1600 (PH), and Radiometer Oxi (RA] into two statistically different subgroups by comparing their InH standard deviation (SD). There is a highly statistically significant difference between the accuracy measured for the high precision subgroup with an InH SD ranging from +/- 1.6 to +/- 1.9% SaO2 (DA, PH, and RA), and that measured for the low precision subgroup whose InH SD ranges from +/- 2.8 to +/- 5.0% SaO2 (NE, OH, NO, KO, PP). These results suggest that, in our clinical conditions, there is a wide range of inhomogeneity of error from one PO to another. The error introduced by the drift of EOS with SfO2 should be considered separately.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2237265     DOI: 10.1080/00365519009089168

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  5 in total

1.  Influence of hypoxic ventilatory response on arterial O2 saturation during maximal exercise in acute hypoxia.

Authors:  H Benoit; T Busso; J Castells; C Denis; A Geyssant
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

2.  Effect of hyperoxia on maximal O2 uptake in exercise-induced arterial hypoxaemic subjects.

Authors:  Olivier Grataloup; Fabrice Prieur; Thierry Busso; Josiane Castells; François B Favier; Christian Denis; Henri Benoit
Journal:  Eur J Appl Physiol       Date:  2005-06-08       Impact factor: 3.078

3.  Increased Small Intestinal Permeability during Severe Acute Exacerbations of COPD.

Authors:  Roy T M Sprooten; Kaatje Lenaerts; Dionne C W Braeken; Ilvy Grimbergen; Erica P Rutten; Emiel F M Wouters; Gernot G U Rohde
Journal:  Respiration       Date:  2018-01-25       Impact factor: 3.580

4.  Decrease in peak heart rate with acute hypoxia in relation to sea level VO(2max).

Authors:  Henri Benoit; Thierry Busso; Josiane Castells; Andre Geyssant; Christian Denis
Journal:  Eur J Appl Physiol       Date:  2003-07-26       Impact factor: 3.078

5.  Exercise-Induced Oxygen Desaturation during the 6-Minute Walk Test.

Authors:  Raghav Gupta; Gregg L Ruppel; Joseph Roland D Espiritu
Journal:  Med Sci (Basel)       Date:  2020-01-31
  5 in total