Literature DB >> 22372528

Continuous regional myocardial blood flow measurement: validation of a near-infrared laser Doppler device in a porcine model.

Benjamin Bierbach1, Jens Scheewe, Thomas Derfuss, Alfons Krug, René Schramm, Manfred Dahm, Wlodzimierz Kuroczynski, Oliver Kempski, Georg Horstick.   

Abstract

OBJECTIVE: RMBF measurement is a major concern in various clinical and experimental settings, but no validated device for RMBF is currently available.
METHODS: An LVP-triggered laser Doppler to measure RMBF was validated by simultaneous fluorescent MS RMBF in a porcine LAD flow reduction model (n = 10 pigs). The laser probe was positioned on the left ventricle's anterior wall. LAD blood flow reduction was achieved by a shaft-driven occluder positioned proximal to the transit-time flow meter measuring coronary blood flow. RMBF was measured at baseline; after the reduction of LAD blood flow to 70% and 30% of baseline; at 20 and 120 minutes of reperfusion; and, finally, 15 minutes after LAD occlusion.
RESULTS: Laser Doppler RMBF (LDU) correlated strongly with MS RMBF under all tested conditions: baseline (epicardial 194.7 ± 41.9, endocardial 130.2 ± 29.2); 70% baseline-flow (epicardial 160.4 ± 27.7, endocardial 112.1 ± 15.1); 30% baseline-flow (epicardial 44.3 ± 5.5, endocardial 32.9 ± 9); 20 minutes reperfusion (epicardial 175.8 ± 33.6, endocardial 126.5 ± 30); 120 minutes reperfusion (epicardial 146.3 ± 31.1, endocardial 107.1 ± 29.7); and complete LAD occlusion (epicardial 10.5 ± 5.8 endocardial 1.4 ± 0.3) (r = 0.986-0.962, p < 0.001).
CONCLUSIONS: This new blood pressure waveform-triggered laser Doppler probe is able to measure RMBF at different depths online in the beating heart.
© 2012 John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22372528     DOI: 10.1111/j.1549-8719.2012.00173.x

Source DB:  PubMed          Journal:  Microcirculation        ISSN: 1073-9688            Impact factor:   2.628


  2 in total

1.  Laser Doppler flowmetry to assess myocardial microcirculation.

Authors:  Jakub Piotrowski; Lech Anisimowicz; Marcin Hellmann
Journal:  Cardiol J       Date:  2020-02-27       Impact factor: 2.737

2.  Improvement of Superficial and Deep Cutaneous Microcirculation Due to Axillary Plexus Anesthesia Impaired by Smoking.

Authors:  Talia Bosselmann; Jonas Kolbenschlag; Ole Goertz; Peter Zahn; Lukas Prantl; Marcus Lehnhardt; Björn Behr; Alexander Sogorski
Journal:  J Clin Med       Date:  2021-05-14       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.