Literature DB >> 22364552

Effect of classroom air quality on students' concentration: results of a cluster-randomized cross-over experimental study.

D Twardella1, W Matzen, T Lahrz, R Burghardt, H Spegel, L Hendrowarsito, A C Frenzel, H Fromme.   

Abstract

UNLABELLED: To assess the effect of indoor air quality as indicated by the median carbon dioxide (CO₂) level in the classroom on the concentration performance (CP) of students, a cross-over cluster-randomized experimental study was conducted in 20 classrooms with mechanical ventilation systems. Test conditions 'worse' (median CO₂ level on average 2115 ppm) and 'better' (median CO₂ level on average 1045 ppm) were established by the regulation of the mechanical ventilation system on two days in one week each in every classroom. Concentration performance was quantified in students of grade three and four by the use of the d2-test and its primary parameter 'CP' and secondary parameters 'total number of characters processed' (TN) and 'total number of errors' (TE). 2366 d2-tests from 417 students could be used in analysis. In hierarchical linear regression accounting for repeated measurements, no significant effect of the experimental condition on CP or TN could be observed. However, TE was increased significantly by 1.65 (95% confidence interval 0.42-2.87) in 'worse' compared to 'better' condition. Thus, low air quality in classrooms as indicated by increased CO₂ levels does not reduce overall short-term CP in students, but appears to increase the error rate. PRACTICAL IMPLICATIONS: This study could not confirm that low air quality in classrooms as indicated by increased CO₂ levels reduces short-term concentration performance (CP) in students; however, it appears to affect processing accuracy negatively. To ensure a high level of accuracy, good air quality characterized, for example, by low CO₂ concentration should be maintained in classrooms.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22364552     DOI: 10.1111/j.1600-0668.2012.00774.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  3 in total

1.  Exposure of research personnel to carbon dioxide during euthanasia procedures.

Authors:  Ashlee A Amparan; Shelly M Djoufack-Momo; Beverly Grunden; Gregory P- Boivin
Journal:  J Am Assoc Lab Anim Sci       Date:  2014-07       Impact factor: 1.232

2.  Combined effects of ventilation rates and indoor temperatures on cognitive performance of female higher education students in a hot climate.

Authors:  Riham Ahmed; Dejan Mumovic; Emmanouil Bagkeris; Marcella Ucci
Journal:  Indoor Air       Date:  2022-02       Impact factor: 6.554

3.  A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study.

Authors:  Jeannette T M Rosbach; Machiel Vonk; Frans Duijm; Jan T van Ginkel; Ulrike Gehring; Bert Brunekreef
Journal:  Environ Health       Date:  2013-12-17       Impact factor: 5.984

  3 in total