Literature DB >> 22362937

Evaluation of the automated hematology analyzer Sysmex XT-2000iV ™ compared to the ADVIA ® 2120 for its use in dogs, cats, and horses. Part II: Accuracy of leukocyte differential and reticulocyte count, impact of anticoagulant and sample aging.

Natali Bauer1, Julia Nakagawa, Cathrin Dunker, Klaus Failing, Andreas Moritz.   

Abstract

The automated laser-based hematology analyzer Sysmex XT-2000iV™ provides a 5-part differential count and specific cytograms that are of great interest for large veterinary laboratories. The aim of the study was to validate the Sysmex XT-2000iV compared to the laser-based hematology analyzer ADVIA® 2120 and manual differential in dogs, cats, and horses as well as the impact of anticoagulant (heparin, ethylenediamine tetra-acetic acid [EDTA], and citrate) and storage at 22°C and 4°C. Consecutive fresh K(3)-EDTA blood samples from 216 cats, 314 dogs, and 174 horses were included. The impact of anticoagulant and sample storage was assessed in specimens obtained from an additional 9 cats, 10 dogs, and 10 horses. Agreement between both analyzers was excellent to good except for monocytes and canine reticulocytes. Spearman rank correlation coefficients (r (s)) between Sysmex XT-2000iV and manual differential were good to fair and ranged from 0.91 (cat lymphocytes) to 0.44 (cat monocytes). Hematocrit value (Hct), mean corpuscular hemoglobin (MCH), MCH concentration (MCHC; all: P < 0.001), and mean corpuscular volume (MCV; P < 0.01) were higher in canine citrated blood compared to heparin and EDTA. In cats, lymphocytes and monocytes were lower in heparinized blood compared to EDTA (P < 0.05), whereas in horses no significant effect was seen. Regarding storage time and temperature, white and red blood cell counts, hemoglobin, and MCH were stable. Hct, MCV, and MCHC were influenced by erythrocyte swelling. Differential count remained stable for 24 hr (22°C) and nearly 72 hr (4°C) except for monocytes. The overall performance of the Sysmex XT-2000iV was excellent and compared favorably with that of the ADVIA 2120. A special strength was the excellent detection of feline eosinophils.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22362937     DOI: 10.1177/1040638711436243

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  8 in total

1.  Heinz body-related interference with leukocyte and erythrocyte variables obtained by an automated hematology analyzer in cats.

Authors:  Francesco Dondi; Kateryna Vasylyeva; Federica Serafini; Marta Gruarin; Roberta Troìa; Massimo Giunti; Chiara Agnoli
Journal:  J Vet Diagn Invest       Date:  2019-07-10       Impact factor: 1.279

2.  Rate of manual leukocyte differentials in dog, cat and horse blood samples using ADVIA 120 cytograms.

Authors:  Martina Stirn; Andreas Moritz; Natali Bauer
Journal:  BMC Vet Res       Date:  2014-06-05       Impact factor: 2.741

3.  Changes of hematological references depends on storage period and temperature conditions in rats and dogs.

Authors:  Jung-Min Lee; Jin Seok Kang
Journal:  Lab Anim Res       Date:  2016-12-23

4.  Diagnostic value of reticulocyte indices for the assessment of the iron status of cats with chronic kidney disease.

Authors:  Adeline Betting; Ariane Schweighauser; Thierry Francey
Journal:  J Vet Intern Med       Date:  2022-01-28       Impact factor: 3.333

5.  Detection of frequent neutrophil misclassification by the ProCyte Dx in sick dogs and how to avoid it.

Authors:  E Bergstrand; H W Tvedten; I Lilliehöök
Journal:  J Small Anim Pract       Date:  2022-03-22       Impact factor: 1.669

6.  Development and evaluation of a novel in-clinic automated hematology analyzer, ProCyte Dx, for canine erythrocyte indices, leukogram, platelet counts and reticulocyte counts.

Authors:  Yasuhito Fujino; Yoichi Nakamura; Hideaki Matsumoto; Kenjiro Fukushima; Masashi Takahashi; Koichi Ohno; Hajime Tsujimoto
Journal:  J Vet Med Sci       Date:  2013-07-01       Impact factor: 1.267

7.  Feline Differential Leukocyte Count with ProCyte Dx: Frequency and Severity of a Neutrophil-Lymphocyte Error and How to Avoid It.

Authors:  H W Tvedten; V Andersson; I E Lilliehöök
Journal:  J Vet Intern Med       Date:  2017-09-01       Impact factor: 3.333

8.  Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats.

Authors:  Kim-Lina Charlotte Zelmer; Natali Bauer; Andreas Moritz
Journal:  J Vet Diagn Invest       Date:  2022-03-24       Impact factor: 1.279

  8 in total